Operation View - Gree DC Inverter Multi VRF Service Manual

Dc inverter multi vrf (t1/r410a/50hz)
Table of Contents

Advertisement

DC INVERTER MULTI VRF

5.2 Operation View

Instruction to functions of buttons (Table 5.1)
No.
Name
FUNC
1
(FUNCTION)
2
MODE
3
4
5
FAN
6
TIMER
7
ON/OFF
2MODE and
Lock
7 ON/OFF
2MODE and
Shield mode
6 TIMER
4 ▼and
Shielding
6 TIMER
Temp.
7 ON/OFF and
Shielding
6 TIMER
ON/OFF
2 MODE and
Memory
3 ▲
mode
4 ▼and
Selection
7 ON/OFF
of function
Note:
1.The characters with gray back ground indicate buttons. Following part is the same to it.
2. The time of single press of the button is more than 3s, which means successively-press.
3. There isn't the function that the region wired controller shields other indoor wired controller.
A. Switch the control mode of inquiry/single/ central control.
B. In central control status, give the central order by successively pressing FUNC
button.
Set cooling/heating/fan/dry mode for indoor unit
A. Inquiry status: cycle, increase or decrease No. of indoor units to easily inquire the
status of each indoor unit.
B. Single/Central control status: set running temp. of indoor unit, maximum is 30
and minimum is 16 .
C. Timer setting status: increase or decrease the timer on/off time, maximum is 24hr
and minimum is 0.
A. Set the indoor fan speed of hi/mid/low/auto.
B. Successively press FAN button to set on/off swing.
A
Under single/central control mode, set on /off timer of selected indoor unit
B
Under inquiry status, inquire the timer setting of the indoor unit with current
address.
Set ON/OFF of the indoor unit.
Under single/central control, press MODE and ON/OFF buttons simultaneously to
start/ stop the lock of operation to buttons of wired controller for selected indoor
units.
Under single/central control, press MODE and TIMER simultaneously to start/ stop
the shield of operation to MODE button of wired controller for selected indoor unit.
Under single/central control, press ▼ and TIMER simultaneously to start/ stop the
shield of operation to Temp button of wired controller for selected indoor unit.
Under single/central control, press ON/OFF and TIMER simultaneously to start/ stop
the shield of operation to ON/OFF button of wired controller for selected indoor unit.
Refer to power-off memory function about the details.
A Check the control mode of region monitoring controller / region wired controller
B Set the control mode of region monitoring controller / region wired controller
Fig.5.2
Function
CONTROL
65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gmv(l)-pd100w/nab-kGmv(l)-pd120w/nab-kGmv(l)-pd140w/nab-kGmv(l)-pd160w/nab-kGmv-r22p/na-kGmvl-r22p/na-k ... Show all

Table of Contents