U-Match Series DC Inverter Service Manual
(9) Wire the swing flap motor as shown in Figure 3-1-48.
1.2.7 Dimension Data
For the units: 24k~48k
Item
Model
GKH24S3GI
GKH36S3GI
GKH42S3GI
GKH48S3GI
1.2.8 Installation of Drain Piping
(1) Keep piping as short as possible and slope it downwards at a gradient of at least 1/100 so that
air may not remain trapped inside the pipe.
(2) Keep pipe size equal to or greater than that of the connecting pipe.
(3) Install the drain piping as shown and take measures against condensation. Improperly rigged
piping could lead to leaks and eventually wet furniture and belongings.
Figure 3-1-48
D
A
I
Table 3-1-49
A
B
950
840
950
840
1040
910
Connect them to the
main body according
to the size of terminals
G
B
Bottom face of ceiling
C
D
770
680
770
680
842
788
64
E
F
134
240
134
290
170
290