Configuring the Switch
3.2.3
Console Time-out
The console can be configured to exit if it does not sense a key stroke within a defined length of time. By default, the
SmartSwitch 6A000 is set to never time-out (value = 0). To activate the time-out feature, use the
command to adjust the time-out period:
SmartSwitch # set consoletimeout
Timeout(0)
Confirm (y/N)? : y
SmartSwitch #
3.2.4
Creating an Alias
Use the
command to create shorter or easier-to-remember names for command lines. For example:
add alias
SmartSwitch # add alias
AliasName()
AliasedString()
SmartSwitch #
The above example creates an alias (
SwitchTrafficCongestion
SmartSwitch # traffic
Queue1EFCIThreshold(4096)
Queue2EFCIThreshold(4096)
Queue3EFCIThreshold(4096)
Queue4EFCIThreshold(4096)
LowEPDWatermark(10922)
HighEPDWatermark(21845)
RMCellMarkingEnable(1)
EFCIMarkingEnable(1)
SmartSwitch #
Enter the
command to display a list of all defined aliases and the command lines to which they correspond.
show alias
:SmartSwitch # show alias
AliasName(ALL)
Alias List
==============================================================================
Index Alias Name
1
PING
2
xxx
3
traffic
SmartSwitch #
: 30 —Will time-out in 30 minutes without input
: traffic
: set switchtrafficcongestion
) that you can enter in place of the command
traffic
. For example:
:
:
:
:
:
:
:
:
:
: Aliased Command
: Start ping
: show portconfig
: set switchtrafficcongestion
set ConsoleTimeOut
set
SmartSwitch 6A000 Installation and Setup Guide 3-7