Datasat AP25 Installation And Operating Manual page 164

Table of Contents

Advertisement

Automation
9. Execute an AP25 Macro
Command:
Response:
This is used to execute a macro defined in the AP25.
Parameters
[Macro]
OK
ERR no macro
Example
Run Macro named Auto1
Send:
Receive:
Level Commands
10. Master Fader Level
Command:
Response:
This is used to set or read the fader level.
Parameters
[New Level]
[Level]
Example
Set the master fader to 7.0
Send:
Receive:
Appendix H. Serial Command AP!
AP25 Installation and Operating Guide
@RUNMACRO<space>[Macro]<CR>
[OK or ERR no macro]<CR>
This is the macro name to execute. The name must match exactly the macro
name on AP25.
Note: Spaces may be used within the name.
Response after macro is found and executed.
Response if macro does not exist on the AP25.
RUNMACRO Auto1
OK
@FADER<space>[New Level]<CR>
FADER<space>[Level]<CR>
Value to set the fader in tenths.
Omit this argument to only read the fader value.
Current master fader level in tenths.
FADER 70
FADER 70
H-8
Document #: 9301H79500 Ver. 1.00