4.3 Grounding device
Connecting the ground cable properly is an important guarantee for lightning
protection, anti-electric shock, and anti-interference. The Gazelle S1000i-LI must be
connected to the ground cable correctly during installation, which helps avoid
personal injury and device damage.
Connect the ground cable as below:
Step 1 Anticlockwise unfasten the screw of the ground terminal and properly keep the screw and
washers taken down, as shown in Figure 4-18.
Figure 4-18 Unfastening the screw of the ground terminal
Step 2 Fit the OT terminal of the ground cable and washers to the screw in order.
Step 3 Install the screw to the ground terminal again and clockwise tighten the screw, as shown in
Figure 4-19.
Figure 4-19 Connecting the ground cable