Environmental Standards; Table 3-4 Environmental Requirements - Raisecom Gazelle S1000i-LI User Manual

Table of Contents

Advertisement

Raisecom
Gazelle S1000i-LI (A) User Manual

3.3.6 Environmental standards

The Gazelle S1000i-LI is applicable to the industrial environment and should meet
environmental requirements shown in Table 3-4.

Table 3-4 Environmental requirements

Air pressure
Operating temperature (altitude: 0–1800 m)
Storage temperature
Operating humidity
Protection level
Environmental authentication
Static electricity meets IEC 61000-4-2 level 3 requirements.
Radiated Immunity Test (RIT) meets IEC 61000-4-3 level 3 requirements.
Electrical Fast Transient (EFT) meets IEC 61000-4-4 level 4 requirements.
Damped oscillation meets IEC 61000-4-12 level 3 requirements.
Surge (impact) meets IEC 61000-4-5 level 4 requirements.
Power Frequency Magnetic Field meets IEC 61000-4-8 level 5 requirements.
Pulse Magnetic Field meets IEC 61000-4-9 level 5 requirements.
Damped Oscillation Magnetic Field meets IEC 61000-4-10 level 5 requirements.
Conducted Immunity (CI) meets IEC 61000-4-6 level 3 requirements.
AC power voltage falling and interruption meet IEC 61000-4-11 requirements.
DC voltage dips and short interruptions immunity meet IEC 61000-4-29 requirements.
Parameter
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
3 Technical specifications
Description
86–106 kPa
-40 to +75° C
-40 to +85° C
5%–95% RH (non-condensing)
IP40
Comply with EU RoHS standard.