Figure 2-3 Lc/Pc Fiber Connector; Table 2-27 Type And Usage Of The Fiber - Raisecom Gazelle S1000i-LI User Manual

Table of Contents

Advertisement

Raisecom
Gazelle S1000i-LI (A) User Manual
The Gazelle S1000i-LI can be connected to the Optical Distribution Frame (ODF) or optical
interfaces of other devices through fiber.
Table 2-27 lists the type and usage of the fiber.

Table 2-27 Type and usage of the fiber

Appearance
Figure 2-3 shows the appearance of the LC/PC fiber connector.

Figure 2-3 LC/PC fiber connector

When connecting or removing the LC/PC fiber connector, align the connector with the optical
interface, and do not rotate the fiber. Operate the fiber as below:
Usage
Connect the Gazelle
S1000i-LI to the ODF
through the Ethernet
optical interface.
Connect the Ethernet
optical interface on the
Gazelle S1000i-LI to
optical interfaces on
other devices.
Choose the connector type and jumper cable length reasonably based on the on-
site requirements.
Choose a connector suitable for the optical interface. Otherwise, it may increase
additional loss of fiber links, reduce transmission quality of services, or even
damage the connector and optical interface.
To connect the fiber, align the header of the fiber with the optical interface and insert the
fiber into the interface gently.
To remove the fiber, press down the clamping connector, and push the fiber header
inwards, and then pull the fiber out.
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Local
Remote
connector
connector
LC/PC
LC/PC
LC/PC
FC/PC
LC/PC
SC/PC
2 Hardware structure
Type
Standard
2-mm SMF
ITU-T
G.652
2-mm MMF
2-mm SMF
2-mm MMF
2-mm SMF
2-mm MMF
35