Laser Safety Class; Reliability Indexes; Safety Standards; Emc Standards - Raisecom Gazelle S1000i-LI User Manual

Table of Contents

Advertisement

Raisecom
Gazelle S1000i-LI (A) User Manual

3.3.2 Laser safety class

The laser inside fiber may hurt your eyes. Do not stare into the optical interface
directly during installation and maintenance.
According to the Tx power of Laser, the Gazelle S1000i-LI laser belongs to Class 1 in safety
class.
In Class 1, the maximum Tx power on the optical interface is smaller than 10 dBm (10 mW).

3.3.3 Reliability indexes

Table 3-3 lists reliability indexes of the Gazelle S1000i-LI.

Table 3-3 Reliability indexes

System availability
Annually system mean repair rate
MTTR
MTBF

3.3.4 Safety standards

The Gazelle S1000i-LI complies with UL60950 standard.

3.3.5 EMC standards

The Gazelle S1000i-LI complies with the following EMC standards:
IEEE 802.1s MSTP
IEEE 802.1x Security
IEEE 802.1p CoS Prioritization
IEEE 802.3x Flow Control
IEEE 802.1ab LLDP
IEC 62351 Power systems management and associated information exchange - Data and
communications security
IEC 61588 Precision clock synchronization protocol for networked measurement and
control systems
IEEE 802.3 Information Technology
IEEE1613 Environmental and testing requirements for communications networking
devices in electric power substations
Parameter
Electro Magnetic Interference (EMI) meets CISPR 22 CLASS A related requirements.
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Description
99.999%. The annual failure time for the Gazelle
S1000i-LI should be no longer than 5 minutes.
< 1.5%
< 2 hours
35 years