3.5.4 Connecting an AUI Cable to an EPIM-X

Caution: The Signal Quality Error (SQE) switch remains in the OFF
position for most network connections. However, some Data Terminal
Equipment (DTE) requires SQE. Refer to your DTE manual for SQE
requirement information.
To connect an EPIM-X to a device not requiring SQE:
1. Check that the SQE LED on the EPIM-X is OFF. If the SQE LED is
ON, check the position of the SQE switch.
Note: If the SQE light remains ON, even though the SQE switch is in
the OFF position, contact Cabletron Technical Support.
2. Attach one end of an AUI cable, no longer than 50 meters in length, to
the port located on the EPIM-X (Figure 3-8) and the other end to the
intended node.
ON Position
(Toward Back
of EPIM)
Page 32
OFF Position
(Toward Front
of EPIM)
Figure 3-8. EPIM-X
TPXMIM Installation Guide