Magtek DynaPro Mini Programmer's Manual page 44

Pin encryption device, commands
Table of Contents

Advertisement

3 - Command Set
Bit
7
Byte 4..63 Block data
Table 3-17 - Response for Command 0x0E
Info ID
Key Status
0x00
1
0x01,0x02
2
0x01
1
0x02
1
0x03
1
0x04
1
0x05
1
0x06
1
0x08
1
0x09
1
0x10
1
0x20 -
-
0x29
0x50
1
0x60 -
1
0x70
0x71 -
1
0x7F
DynaPro Mini| PIN Encryption Device | Programmer's Manual (Commands)
6
5
Data
length
lbllen*
Auth key label
20
KSN
20
KSN
20
KSN
SN & subject's DN**
<=59
SN & subject's DN**
<=59
<=19
Label and KCV
<=19
Label and KCV
Customer ID (4 byte
integer), Signing Sequence
12
Number (4 byte integer),
Upgradability Options (4
byte integer)
<=19
Label and KCV
4 slots for bitmap data
[status + 2 bytes CRC]
4 x 3
status: 0 = not loaded
1 = loaded
-
-
Keypad sensitivity
Tamper sensitivity
Key on threshold
9
Key off threshold
4 bytes keypad threshold
Keypad calibration result
SN & subject's DN**
<=59
SN & issuer's DN**
<=59
Page 44 of 128 (D99875629-43)
4
3
Data
If authorization key exists
If no more keys
PIN key
MSR key
If PIN cert exists
If MSR cert exists
If authorization key exists
If fixed key exists
0x0000000 is Generic Customer
Signing Sequence typically starts
at 0x00000000 and must advance
with each upgrade.
Upgradability values:
0x00000000 = Generic Only
0x00000001 = Specific Only
0x00000002 = Generic or Specific
Acquirer Master Key
Bitmap data status and its CRC
RESERVED
Keypad values
(Cap Keypad Only)
If associated CA cert exists***
If associated CA cert exists***
2
1
0
Description

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DynaPro Mini and is the answer not in the manual?

Questions and answers

Table of Contents