33.111
Relationship to
parameter:
The value from the motor's type plate data has to be entered here for the power factor cos phi.
33.112
Relationship to
parameter:
The torque can be increased here at low frequencies. This parameter determines the output voltage at 0 Hz for increasing
the available torque at low speeds.
Note:
If the breakaway torque isn't sufficient, we would recommend setting parameter 33.010 drive type to 20:
33.201
Relationship to
parameter:
The automatically calculated value (of motor identification) for nominal flux can be adjusted here.
33.248
Relationship to
parameter:
The automatically calculated value (of motor identification) for series inductance can be adjusted here.
33.249
Relationship to
parameter:
The automatically calculated value (of motor identification) for shunt inductance can be adjusted here.
Operating manual for DGM Modular | DOC02389740-0006 | 2021-07 | V1.70 EN
Motor cos phi
Transfer status:
1
Drive type
Boost v/f
Transfer status:
1
Drive type
Nominal flux
Transfer status:
1
Drive type
d inductance
Transfer status:
1
Drive type
q inductance
Transfer status:
1
Drive type
Unit:
min.:
0.5
Own value (to be entered!)
max.:
1
def.:
0
V/f
ASM
PMSM
x
Unit: V
Own value (to be entered!)
min.:
0
max.:
200
def.:
0
V/f
ASM
PMSM
x
Unit: mVs
min.:
0
Own value (to be entered!)
max.:
10000
def.:
0
V/f
ASM
PMSM
x
Unit: H
min.:
0
Own value (to be entered!)
max.:
1
def.:
0
V/f
ASM
PMSM
x
Unit: H
Own value (to be entered!)
min.:
0
max.:
1
def.:
0
V/f
ASM
PMSM
x
SRM
x
SRM
ASM open-loop.
SRM
SRM
SRM
71