8.5.10.1 The sequencer's hardware real time controllers

All of the real-time controls concerning the sequencer are based on the hardware [SEQUENCER]
section located in the bottom of the front Origin panel. These controllers allow you to set all the
most important parameters of the step sequencer.
-
The [Play/Stop] button toggles the sequencer "on" or "off". When set to "on", the
sequencer starts running when a note is pressed and stop when the last note is released.
-
The [Hold] button toggles hold "on" or "off". When hold is "on", the current playing
sequence loops until the [Hold] button is pressed again.
-
The [Frequency] encoder sets the speed of the sequencer. The speed is quantized from
the basic internal tempo, or the MIDI tempo if the MIDI Sync is active.
The [Play/Stop], [Hold] buttons and the [Frequency] encoder
-
The [Seq1...3 Act] buttons activate or deactivate sub-sequence 1...3.
-
The [Edit> Seq1... Seq3, Pattern] button selects the corresponding sequence for editing
or, when [Pattern] is selected, activates pattern selection mode.
-
The [Assign] button opens the "assign" pop-up of the selected sub-sequence.
-
The [Trig] button activates the key trigger on the current step of the selected sub-
sequence.
NOTE: The [Trig] input is usually connected to an envelope output (plugged on a filter cutoff or on
a VCA volume, for example).
-
The [Accent] button activates the accent envelope on the current step of the selected
sub-sequence.
NOTE: Connect the accent input to a filter cutoff frequency FM output to get the famous TB303's
accent effect.
-
The [Slide] button activates the slide function on the current step of the selected sub-
sequence. It gives an effect of portamento between the selected step and the following
step.
-
The [Lock] button allows holding a particular step to it self. This button locks the
currently playing step until the [Lock] button is pressed again to deactivate it. This option