Using the Console
2p›F
When you accept the (
abridged.
2.5.2
Console Time-out
The console can be configured to exit if it does not sense a key stroke within a defined length of time. By default, the
SmartCell 6A000 is set to never time-out (value = 0). To activate the time-out feature, use the
command to adjust the time-out period:
SmartCell ZX # set consoletimeout
Timeout(0)
Confirm (y/N)? : y
SmartCell ZX #
2.5.3
Creating an Alias
Use the
command to create shorter or easier-to-remember names for command lines. For example:
add alias
SmartCell ZX # add alias
AliasName()
AliasedString()
SmartCell ZX #
The above example creates an alias (
SwitchTrafficCongestion
SmartCell ZX # traffic
Queue1EFCIThreshold(4096)
Queue2EFCIThreshold(4096)
Queue3EFCIThreshold(4096)
Queue4EFCIThreshold(4096)
LowEPDWatermark(10922)
HighEPDWatermark(21845)
RMCellMarkingEnable(1)
EFCIMarkingEnable(1)
SmartCell ZX #
Enter the
command to display a list of all defined aliases and the command lines to which they correspond.
show alias
:SmartCell ZX # show alias
AliasName(ALL)
Alias List
==============================================================================
Index Alias Name
1
PING
2
xxx
3
traffic
SmartCell ZX #
2-10 SmartCell 6A000 User Guide
) default for
all
: 30 <Will time-out in 30 minutes without input
: traffic
: set switchtrafficcongestion
) that can be entered in place of the command
traffic
. For example:
:
:
:
:
:
:
:
:
:
: Aliased Command
: Start ping
: show portconfig
: set switchtrafficcongestion
, the information displayed is often
show
Switch Installation and Setup
set ConsoleTimeOut
set
Need help?
Do you have a question about the SmartCell 6A000 and is the answer not in the manual?
Questions and answers