To query the serial mode status, use:
By default, the RS-485 termination resistor is disabled. To enable or disable the RS-485
termination resistor, use the following Linux command:
To query the termination resistor status, use:
To make the rs485.py script executable, use the following command:

Default port settings

Serial:
AT commands:
USB0 serial:
Note: The FX30S does not support PPP.
Using the FX30S as an Embedded Platform for IoT
Applications
To configure or program the FX30S, you can use:
Rev. 5 September 2020
rs485.py/sys/devices/platform/msm_serial_hsl.0/rs_mode
which will return either RS232 or RS485.
rs485.py/sys/devices/platform/msm_serial_hsl.0/rs485_term <NEW
MODE>
Where <NEW MODE> is either:
· 0—RS-485 termination resistor is disabled (drives GPIO63 high; the termination
resistor is active low) (default)
· 1—RS-485 termination resistor is enabled (drives GPIO63 low)
For example, to enable the RS-485 termination resistor: rs485.py/sys/devices/
platform/msm_serial_hsl.0/rs485_term 1
rs485.py/sys/devices/platform/msm_serial_hsl.0/rs485_term
which will return either DISABLED or ENABLED.
chmod a+x rs485.py
/dev/ttyHSL0
115200 8N1
No flow control
/dev/ttyAT
38400 8N1
No flow control
/dev/ttyUSB0
9600 8N1
No flow control
AT Commands—see
AT Commands Reference
Linux Shell Commands—see
Legato Application
Framework—Legato Application Framework
on page 67