Reboot the RV50 Series Gateway

To reboot the RV50 Series gateway:
Reset the RV50 Series Gateway to Factory
Default Settings
To reset the gateway to the factory default settings:
Tip:
authentication settings such as the network ID, network password, custom APNs, Primary SIM, and
Mobile Network Operator firmware when the gateway is reset to the factory default settings. For
more details, refer to the ALEOS Software Configuration User Guide (Admin chapter).

Recovery Mode

If the router fails to boot properly, it automatically enters recovery mode, or, if the router is
unresponsive to ACEmanager input and AT commands, you can manually put the router
into recovery mode.
Recovery mode enables you to update the ALEOS software and return the router to
working order. (For details, refer to the ALEOS Software Configuration User Guide—
Configuring your router chapter.)
To enter Recovery mode manually:
To recover the router:
Note: After the recovery, you need to reload the radio module firmware store and templates.
To exit Recovery mode, if it has been inadvertently entered, do one of the following:
Rev. 6 October 2021
On the gateway, press the Reset button for 1–5 seconds. (Release the button when
the Power LED flashes green.)
In ACEmanager, click the Reboot button on the toolbar.
On the gateway, press the Reset button for more than 5 seconds. (Release the button
when the Power LED flashes red.)
Once the LEDs resume their normal operating behavior, the reset is complete.
In ACEmanager, go to Admin > Advanced and click the Reset to Factory Default
button.
In ACEmanager, you can configure the RV50 Series gateway to preserve mobile network
On the router, press the Reset button for more than 20 seconds. (Release the button
when the Power LED flashes amber.)
Update ALEOS using the Recovery mode interface. Once the new ALEOS version is
successfully uploaded and installed, the gateway reboots and exits recovery mode.
When the process is complete, the ACEmanager login screen appears.
Press the reset button on the gateway to reboot it.
Click the Reboot button on the Recovery screen.