Proflame 2
Remote Control
Features Overview
The Proflame 2 Integrated Fireplace Control (IFC)
incorporates electronic remote control of the Jøtul GF
400 DV IPI features. It is configured to control the on/
off operation both manually and thermostatically, with
standard and "Smart" thermostat features. It will also
control flame modulation, fan power and speed, accent
lighting function and level.
The burner utilizes an IPI system (Intermittent Pilot
Ignition) and may also be switched to keep the pilot lit
continuously if desired (CPI - Continuous Pilot Ignition).
CPI NOTE: The pilot light will automatically extinguish
after 7 days. It will automatically re-ignite at the next call
for heat, either manualy or thermostatically.
If left under thermostatic control, the unit will switch to
IPI mode allowing the pilot to ignite only when there is a
call for heat.
Power is provided to the IFC by 120V house current. In
the event of a power failure, burner operation is backed-
up by a 6V battery pack (four, 1.5v AA).
Remote Control Transmitter
The remote transmitter has all controls available on its
face for reliable, ease of use. It gives room temperature
readout, set temperature readout, all function abilities as
well as childproof lockout and low battery indicator. Icons
appear on the screen indicating which mode of operation
you are controlling. The four button controls are easy to
learn and simple to operate. The transmitter is powered
by 3, 1.5V AAA batteries.
Remote Control Receiver
The receiver is integrated with the IFC board which is
located within the valve compartment.
Integrated Fireplace Control (IFC)
The IFC is the electrical heart of the system. It provides
power to all components and converts to 6.5v DC in
the event of power failure. The IFC sends power to the
fan system and the accent light. When no line power is
available these features will not operate, however the
battery back-up allows remote control of burner operation.
Sit 885 Modulating Valve
This valve has the ability to be stepped down in six
increments between high and low. It can be done
manually or by setting the remote control to the Smart
thermostat modulation mode. Automatic modulation
means that as the room temperature approaches the
28
limit set for shut down, the valve gradually decreases
or "steps-down" the fire intensity. Conversely, as room
temperature cools, the valve gradually increases flame
intensity.
The overall result is more comfortable, even heating that
minimizes temperature peaks and valleys.
Pilot Assembly
The pilot contains a pilot hood, igniter, and a flame
sensor. The igniter sends a spark to the pilot hood which
lights the gas. The sensor is then engulfed by the pilot
flame, flame rectification occurs and the unit remains lit.
If rectification does not occur, the main burner will not
light, and the pilot will shut down.
WARNING:
READ AND UNDERSTAND ALL OPERATING
INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE
THIS APPLIANCE. DO NOT ALLOW ANYONE TO
OPERATE THIS APPLIANCE WHO HAS NOT READ
AND UNDERSTOOD THESE INSTRUCTIONS. KEEP
THE REMOTE CONTROL TRANSMITTER WHERE
CHILDREN CANNOT REACH IT.
WARNING:
SEVERE INJURY. THIS APPLIANCE CAN BE SET TO
OPERATE THERMOSTATICALLY. BE AWARE THAT
THE FIREPLACE MAY BE VERY HOT EVEN WHEN
THE BURNER IS NOT APPARENTLY OPERATING.
KEEP CHILDREN AWAY FROM THE APPLIANCE.
WARNING:
FIRE HAZARD. CAN CAUSE SEVERE INJURY OR
DEATH. THE APPLIANCE CAN TURN ON SUDDEN-
LY. KEEP AWAY FROM THE APPLIANCE BURNER
WHEN OPERATING THE REMOTE SYSTEM.
WARNING:
OBSERVE CAUTION NEAR THE GLASS PANEL.
THE GLASS MAY SHATTER IF STRUCK BY AN OBJECT.
ALWAYS HANDLE THE GLASS PANEL WITH CARE.
ATTENTION:
• TURN "OFF" MAIN GAS SUPPLY PRIOR TO
REMOVING OR REPLACING BATTERIES.
• IN CASE OF REMOTE CONTROL MALFUNCTION,
TURN OFF THE IFC DEVICE USING THE MAIN
"ON/OFF" SWITCH.
• FOR INSTALLATION/MAINTENANCE SWITCH
"OFF" THE IFC DEVICE BY DISCONNECTING THE
MAIN POWER SUPPLY PLUG.