Location; Hearth Protection; Clearances - Jøtul GF 400 DV IPI Sebago Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

139548-N GF 400 DV IPI 7/21

Location

In selecting a location for the stove, consider the
following points:
1) Heat distribution
2) Vent termination requirements
3) Gas supply line routing
4) Traffic areas, furniture, draperies, etc.
The GF 400 DV IPI may be located on or near conven-
tional construction materials, however, proper clearance
to combustibles must be maintained in order to provide
adequate air circulation around the appliance. Also, it is
important to provide adequate access around the stove
for servicing and proper operation.
The clearance and hearth specifications listed in this
manual are the minimum requirements for combustible
material. A combustible material is anything that can
burn (i.e. sheet rock, wall paper, wood, fabrics etc.). These
surfaces are not limited to those that are visible and also
include materials that may be located behind non-com-
bustibles.
If you are not sure of the combustible nature of a
material, consult your local fire officials. Remember, "Fire
Resistant" materials are considered combustible: they are
difficult to ignite, but will burn. Also, "fire-rated" sheet
rock is considered combustible.
Hearth Requirements
This appliance CANNOT be installed directly on carpeting,
vinyl, linoleum or wood laminate flooring, such as Pergo
If this appliance will be installed on any combustible
material OTHER THAN WOOD, a floor pad must be in-
stalled that is either metal, wood, ceramic tile, stone, or a
listed hearth pad. This floor protection must extend the
full width and depth of the appliance. It is not necessary
to remove carpeting, vinyl or linoleum from underneath
the floor protection. See fig. 1.
Figure 1.
6
14"
(356 mm)
27"
(686 mm)
Stove and Vent Clearance
Requirements
The clearances specified and diagrammed here are es-
tablished from the stove body. The safety barrier has no
affect on clearances to combustible material.
Minimum Clearances from the Stove
to Combustibles:
Rear:
2" (51 mm)
Ceiling:
32 1/4" (819 mm)
Corner:
2" (51 mm)
Sides:
3" (76 mm)
Minimum Clearances from the Vent Pipe to
Combustibles:
Horizontal Run:
Off the top of the pipe
Off the sides and bottom 1" (25 mm)
Vertical Run:
All sides
1" (25 mm)
®
.
3"
(76 mm)
Figure 2. Parallel Installation Clearances.
2"
51 mm
Figure 3. Corner clearances.
See figs. 2-4.
2" (51 mm)
2"
(51 mm)
To Rear Wall
3"
(76 mm)
2"
51 mm