Jøtul GF 400 DV IPI Sebago Installation And Operation Instructions Manual

Jøtul GF 400 DV IPI Sebago Installation And Operation Instructions Manual

Direct vent gas stove

Advertisement

139548-N GF 400 DV IPI 7/21
Jøtul GF 400 DV IPI
Sebago
Direct Vent Gas Stove
Pilot on Demand Ignition
Installation and
Operation Instructions
Certified to ANSI Z21.88-2016 • CSA 2.33-2016 and
CAN/CGA 2.17-M-17.
Conforms to Canadian Energy Efficiency
Regulations, Amendment 15 - 2018
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
CANADIAN ENERGY PERFORMANCE VERIFIED
RENDEMENT ÉNERGÉTIQUE VÉRIFIÉ
EP5010378
1
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
– Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
– In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall
be installed in the same room as the
appliance.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or
mobile home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is
supplied with the appliance.
DANGER
!
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the burn hazard
from the glass viewing area is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
HOT GLASS WILL
CAUSE BURNS
.
UNTIL COOLED.
TO TOUCH GLASS.

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GF 400 DV IPI Sebago

  • Page 1 139548-N GF 400 DV IPI 7/21 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Service Tools

    139548-N GF 400 DV IPI 7/21 Installation Requirements for the THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE Commonwealth of Massachusetts OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ THIS PRODUCT MUST BE INSTALLED BY THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM A LICENSED MASTER OR JOURNEYMAN AVAILABLE TO ANYONE USING OR SERVICING THIS GAS PLUMBER OR GAS-FITTER WHEN...
  • Page 3: Table Of Contents

    Fuel Conversion ........15 reference. Gas Connection ........17 MODEL NAME: Jøtul GF 400 DV IPI Sebago Gas Stove Gas Pressure ..........18 SERIAL NUMBER:_______________________________ High Altitude Adjustment ....18 Optional Brick Panel Installation ..19 DATE OF PURCHASE:____________________________ Log Set Installation .......
  • Page 4: Specifications

    139548-N GF 400 DV IPI 7/21 GF 400 DV IPI Sebago General Information Specifications THIS HEATER MUST BE INSTALLED AND MAINTAINED  BY A QUALIFIED SERVICE AGENCY. Input Rates The installation and repair of this appliance must be  Natural Gas done by a qualified service person.
  • Page 5: Unpacking Your Stove

    139548-N GF 400 DV IPI 7/21 Safety Information DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN  UNDER WATER. Call a qualified service technician to  Due to the high operating temperatures this appliance should be located out of traffic and away from inspect the heater and to replace any part of the con- furniture and draperies.
  • Page 6: Location

    139548-N GF 400 DV IPI 7/21 Stove and Vent Clearance Location Requirements In selecting a location for the stove, consider the following points: The clearances specified and diagrammed here are es- 1) Heat distribution tablished from the stove body. The safety barrier has no 2) Vent termination requirements affect on clearances to combustible material.
  • Page 7: Mantel & Trim

    139548-N GF 400 DV IPI 7/21 Minimum Ceiling or Alcove Height Max. Mantel Depth 12.5” Max. Mantel Depth 12.5” 10.25” 10.25” 8” 8” 5.75” 5.75” 3.5” Min. Mantel Depth 3.5” Min. Mantel Depth Max. Trim Max. Top Trim Depth = 1” 2”...
  • Page 8: Vent Requirements

    139548-N GF 400 DV IPI 7/21 Venting Requirements • IF VENTING SYSTEM IS DISASSEMBLED FOR ANY REASON, REINSTALL PER THE INSTRUCTIONS PROVIDED The Jøtul GF 400 DV IPI gas stove requires 4” x 6 5/8” co- FOR THE INITIAL INSTALLATION. axial, direct vent pipe components and may be installed with a vertical or horizontal termination.
  • Page 9: Termination Matrix

    139548-N GF 400 DV IPI 7/21 Figure 8. Exhaust restrictor positions - viewed from front with top plate removed. RESTRICTION FULL RESTRICTION 35 Ft. (10.67 m) 30 Ft. (9.14 m) TERMINATION APPROVED 24 Ft. (7.31 m) 20 Ft. (6.10 m) 15 Ft.
  • Page 10: Vertical Termination

    139548-N GF 400 DV IPI 7/21 Vertical Vent Termination Horizontal Overhang The Jøtul GF 400 DV IPI can be vertically vented through a ceiling or to a roof termination with the following 18”. 18”. guidelines: min. min. The termination should fall within the shaded areas of ...
  • Page 11 139548-N GF 400 DV IPI 7/21 Co-linear Vent Installation High Wind Cap Exhaust Gas The GF 400 DV IPI may be vented through a masonry or Class A prefabricated chimney using a Co-linear Flexible Vent system approved for use with a solid-fuel burning Max.
  • Page 12: Horizontal Termination

    139548-N GF 400 DV IPI 7/21 Horizontal Termination 12 in. (305mm) Any horizontal termination must fall within the shaded  portion of the vent window matrix shown in fig. 9. For Snorkel Terminations, see page 13. Any horizontal termination except a snorkel termina- ...
  • Page 13 139548-N GF 400 DV IPI 7/21 DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION. Any horizontal run of vent must be level or have a  1/4 in. rise for every foot of run toward the termination cap. NEVER ALLOW THE VENTING TO RUN DOWNWARD 36 in.
  • Page 14: Vent Terminal Clearances

    139548-N GF 400 DV IPI 7/21 Horizontal Termination Clearance 2 1/2” 12 ” 64 mm 3” 76 mm Figure 19. Termination Clearance to overhangs. Vent Terminal Figure 18. Vent Terminal Clearances, Canada and United States Air Supply Terminals Prohibited in this Area Canadian Installations U.S.
  • Page 15: Mobile Home Installation

    139548-N GF 400 DV IPI 7/21 Mobile Home Installation WARNING: THE CONVERSION KIT IS TO BE INSTALLED BY The GF 400 DV IPI can be installed for use in a mobile AN AUTHORIZED SERVICE TECHNICIAN IN home in the U.S. and Canada provided: ACCORDANCE WITH THE MANUFACTURER’S 1.
  • Page 16 139548-N GF 400 DV IPI 7/21 Fuel Conversion Procedure 1. Turn off gas supply to stove. 2. Remove the stove Top Plate. 3. Disengage the two Glass Frame Latches and lift the glass panel frame up and out of the stove. 4.
  • Page 17: Gas Connection

    139548-N GF 400 DV IPI 7/21 Fuel Conversion, cont’d. 15. Correct gas pressure is essential for efficient and safe operation of this appliance. Use a manometer to check LEAK TEST pressures as specified in the Gas Pressure section of this manual (page 18). WARNING! 16.
  • Page 18: Gas Pressure

    139548-N GF 400 DV IPI 7/21 Gas Pressure High Altitude Adjustment Correct gas pressure is essential for efficient and LP Kit #157613 safe operation of the GF 400 DV IPI gas stove. It is NG Kit #157614 important that the correct pressure is established The decreased atmospheric pressure of higher alti- at the time of the installation.
  • Page 19: Optional Brick Panel Installation

    139548-N GF 400 DV IPI 7/21 CAUTION! THE BRICK PANELS ARE FRAGILE. SUPPORT THE PANELS WITH BOTH HANDS AND HANDLE WITH CARE. Upper Panel 1. Install the Lower Panel. 225004 Position it up against the back wall, resting on the burner skirt.
  • Page 20: Log Set Installation

    139548-N GF 400 DV IPI 7/21 Log Set Installation Brick Kit Note: Install the optional Reversable Panel Kit 157603 before installing the log set. See page 19 or the instructions provided with that kit. The GF 400 DV IPI log set must be installed before operating the burner.
  • Page 21: Optional Wall Thermostat

    139548-N GF 400 DV IPI 7/21 Optional Wall Thermostat Use only a 750 millivolt DC two-wire circuit wall thermostat with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat.
  • Page 22: System Check

    139548-N GF 400 DV IPI 7/21 System Check 1. PURGING THE GAS LINE: When lighting the appliance WARNING: for the first time, it will take a few moments to clear AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE the gas line of air. Once this purge is complete, the PERFORMED BY A QUALIFIED, PROFESSIONAL appliance will operate as described in the lighting SERVICE TECHNICIAN.
  • Page 23: Flame Picture Adjustment

    139548-N GF 400 DV IPI 7/21 Flame Appearance / Air Shutter Adjustment The GF 400 DV IPI gas stove is shipped from the factory equipped to burn Natural gas. If the stove has been converted for use with propane, the Air Shutter adjustment range should be limited using the stop screw supplied with the conversion kit.
  • Page 24: Manual Operation

    139548-N GF 400 DV IPI 7/21 Manual Operation Familiarize yourself with the controls of the GF 400 DV IPI WARNING: and be sure that anyone else using the appliance is also READ AND UNDERSTAND ALL OPERATING familiar with the controls and operation procedures. Always INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE follow the Lighting Instructions on the inside back cover of THIS APPLIANCE.
  • Page 25: Maintenance

    139548-N GF 400 DV IPI 7/21 Maintenance NOTE: INSPECT THE GLASS SURFACE FOR SCRATCHES Your Jøtul GF 400 DV IPI Sebago components and its AS THESE CAN WEAKEN THE PANEL TENSILE STRENGTH. venting system should be inspected before use and at REPLACE THE PANEL IF ANY SCRATCHES ARE FOUND.
  • Page 26: Flame Control

    139548-N GF 400 DV IPI 7/21 Accessories Accent Lamp Contents: Tools Required: Premium Upgrade Kits 1. Lamp Box Assembly w/ harness • 10 mm wrench 2. Lens • Safety goggles #157498 - NG 3. Gasket • Work gloves #157499 - LP 4.
  • Page 27: Blower & Multifunction Remote

    29-32. Figure 45. Route the lamp harness between the heat shield and the cast iron side panel. Outer Shroud Lamp Harness Lamp and Blower Connections Figure 46. 157470 Blower Kit Components used for GF 400 DV IPI Sebago.
  • Page 28: Remote Operation

    139548-N GF 400 DV IPI 7/21 Proflame 2 limit set for shut down, the valve gradually decreases Remote Control or “steps-down” the fire intensity. Conversely, as room temperature cools, the valve gradually increases flame intensity. Features Overview The overall result is more comfortable, even heating that minimizes temperature peaks and valleys.
  • Page 29 139548-N GF 400 DV IPI 7/21 Control Functions Initializing the System 1. Press the Controls Access Door to release its magnetic Pilot Mode catch and swing the panel down. Switch the Burner to OFF. See fig. 40, pg. 25. Set the stove switch to CPI mode for Proflame 2 remote control.
  • Page 30 139548-N GF 400 DV IPI 7/21 Remote Transmitter Controls Temperature Indication Display With the transmitter in the OFF position, press the  Thermostat Key and the Mode Key at the same time. The display screen will show the current room temperature cycling between Fahrenheit and Celsius indicators each time the keys are pressed Figure 49.
  • Page 31 139548-N GF 400 DV IPI 7/21 Room Thermostat (Transmitter Operation) Room Temperature The Remote Control can operate as a room thermostat. The thermostat can be set to a desired temperature to control the comfort level in a room. To activate this function, press the Thermostat Key. The ...
  • Page 32: Wiring Diagram

    Optional Variable Speed Blower Figure 67. GF 400 DV IPI Sebago with Proflame 2 Premium Remote Control Accessories IFC Battery Replacement A red LED on the IFC board indicates low battery power. 1. Switch Burner to OFF and disconnect power to the stove.
  • Page 33: Illustrated Parts Lists

    139548-N GF 400 DV IPI 7/21 GF 400 DV IPI Sebago Illustrated Parts Breakdown Figure 68. GF 400 DV IPI Cast iron parts and associated hardware. Brown Green Cast Iron Matte Black Blue Black Ivory Majolica Majolica Parts Paint Enamel...
  • Page 34 139548-N GF 400 DV IPI 7/21 YEL/GRN Figure 69. GF 400 DV IPI Valve Assembly and IFC Components. Part No. Description 117975 Wing Nut, M6 Zinc No. Part No. Description 224145 Magnetic Catch - Push to open 117917 Screw, #8 x 1/2” SL Blk Oxide 9962 Bolt, Hex Hd Serr Flng M6 x 10mm 224904...
  • Page 35 139548-N GF 400 DV IPI 7/21 Install #1 with any Snorkel termination. Bottom of Firebox Fig. 70a. Install #2, 3, and 22 ONLY GF 400 DV IPI with Natural Compression fuel Gas Snorkel line assembly. Ttermination. See part listing 70a below. Figure 70.
  • Page 36: Accessory Listing

    139548-N GF 400 DV IPI 7/21 Figure 72. Figure 71. GF 400 DV IPI Glass Assembly GF 400 DV IPI Accent Lamp Assembly GF 400 DV IPI Accessories No. Part No. Description Description Part No. 117967 Screw, Pan Head #7 x 3/8 PH Zinc Premium Upgrade Kit / NG* 157498 157601...
  • Page 37: Appendix

    139548-N GF 400 DV IPI 7/21 Appendix Pilot Tray Installation FOR USE ONLY ON SNORKEL TERMINATED STOVES USING NATURAL GAS. 1. The Pilot Tray is shipped flat in the Miscellaneous Hard- ware bag. Bend it up on the perforatioins as shown in fig.
  • Page 38: Warranty Statement

    139548-N GF 400 DV IPI 7/21 Jøtul Gas Product 2) Damage due to incorrect installations not in conformance with the Warranty installation instructions contained in this owner’s manual or local and/or national fire and building regulations. 3) Damage due to service performed by an installer, service agency or gas supplier, unless otherwise agreed to in writing by JØTUL.
  • Page 39: Lighting Instructions

    139548-N GF 400 DV IPI 7/21 LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. This appliance is equipped with an ignition device •...
  • Page 40 139548-N GF 400 DV IPI 7/21 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

Table of Contents