Error Messages - VETRON 5374 Service Manual

Hotair welding machine
Table of Contents

Advertisement

03. COMMISSIONING & WELDING

08. ERROR MESSAGES

-1-2
DISPLAY
» ERROR-LIST
E1
Pressure system
E2
can't initialize
Anvil sensor no
E3
response
E4 Control panel
E5 Memory full
E6 Power supply
EEPROM memory
E7
too small
Number of Parameters
E8
too high
E9 Head PCB no response
E10 Auto gap processor error
E11 Stepper error
E12
E13 Position read error
E14 Interval memory full
E15 No interval programmed Interval programm without interval setting
E16 Index overrun
02/2021
26
Vetron 5374 HotAir-Welding
DESCRITPION
Stepper, sensor PCB, cables
Magnet strip, gap, cables
Head Base memory full
Sytem error
Reserved parameter space overflow
Cable, PCB damaged
Step driver malfunction
Stepper position read error
Maximum interval reached
Memory full
SOLUTION
Check pressure mechanical system
and sensor PCB
Check magnet strip and its gap to encoder
chip on PCB
Delete unused programs
Call Typical
Call Typical
Check cables, call Typical
Restart, check cables
Add interval(s) to program
Call Typical