Before You Begin; Technical Data - Assa Abloy NORTON RIXSON D6051 Series Installation Instructions Manual

Double unit pull side power operator
Hide thumbs Also See for NORTON RIXSON D6051 Series:
Table of Contents

Advertisement

Before You Begin

y All dimensions are given in inches. DO
NOT scale drawings.
y Thickness recommended for
reinforcements in hollow metal doors
and frames is charted.
y This template information based upon
use of 5" maximum width butt hinges.
y Maximum frame reveal is 1/8" for D6011
units and 1/8" up to 3" maximum for
D6051 units.
y Before beginning the installation,
verify that the door frame is properly
reinforced and is well anchored in the
wall. Frame header must be straight -
without warp or bow.
y Unreinforced hollow metal frames and
aluminum frames should be prepared
and fitted with 1/4-20 blind rivet nuts,
furnished by others.
y Concealed electrical conduit and
concealed switch or sensor wires
should be pulled to the frame before
proceeding.

Technical Data

Input power:
Power
consumption:
Circuit breaker:
Power supply:
Door width:
Door weight:
Door opening
angle:
Hold open time: 0-30 seconds (A.D.A. 5 seconds min.)
4
D6011/D6051 Series Double Unit Pull Side Power Operator
Fasteners for Frame:
y 1/4-20 Machine screws for
y #14 x 2-3/4" (70mm) long sheet
Mounting Hardware
Backplate:
14 x 1-1/2 Oval Head Self Drilling Screw
Backplate:
1/4-20 x 1 Flat Head Machine Screw
Backplate:
1/4-20 x 5/8 Flat Head Machine Screw
Track:
Sex Nut and Bolt (SNB)
(optional)
120VAC, 60Hz
.9 amps
3 amps
24 V DC, max. 2.2 amp.
36" - 48" (91-122 cm)
100-250 lb. (43-113 kg)
up to 110° with reveal of 3" (7.6 cm) max
Indefinite for optional Infinite Hold
Open
Copyright © 2019, 2020, 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Approved 2023-01-24
hollow metal and aluminum.
metal screws for wood.
Hollow Metal Door Frame Reinforcing
Frame Material
12 Ga.
.105
(2.66)
14 Ga.
.075
(1.90)
16 Ga.
.060
(1.52)
18 Ga.
.048
(1.21)
Door or Frame
Wood
Metal
Hollow Metal
Aluminum or Wood
NOTES:
y Permanent wiring is to be implemented as
required by local codes.
y Activation devices: push plates, access control,
mats, touchless wall switches, etc.
y Maximum wire size is:
‒ 12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
mounted on inside of end cap.
‒ 14AWG at all other terminals
y Rate of operation shall not exceed 300 cycles of
opening and closing per hour.
Templating based on 1/8" gap between
door and frame.
Reinforcing
Recommended
Min. Required
12 Ga.
18 Ga.
.105
.048
(2.66)
(1.21)
10 Ga.
12 Ga.
.134
.105
(3.41)
(2.66)
10 Ga.
12 Ga.
.134
.105
(3.41)
(2.66)
8 Ga.
10 Ga.
.164
.134
(4.18)
(3.41)
Drill
3/16" (4.76mm)
Drill #7 (.201 dia. or 5.10mm)
Tap 1/4-20
9/32" (7.00mm) thru
3/8" (9.50mm) door face opposite to closer
3/8" (9.50mm) thru
80-9360-1029-020 Rev 6 01/23
Frame
Door
1/8"
(3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton rixson d6011 series