Before You Begin; Mounting Hardware Chart; Technical Data - Assa Abloy Norton D6001DE-R Double Unit Series Installation Instructions Manual

Power operator
Table of Contents

Advertisement

Before You Begin

All dimensions are given in inches .
DO NOT scale drawings .
Thickness recommended for reinforcements
in hollow metal doors and frames is charted .
This template information based upon use of
5" maximum width butt hinges .
Frame reveal is 2-1/4" to 4-3/4" for push arm
and 1/8" to 3" for pull arm .
Before beginning the installation, verify that
the door frame is properly reinforced and is
well anchored in the wall . Frame header must
be straight - without warp or bow .
Unreinforced hollow metal frames and
aluminum frames should be prepared and
fitted with 1/4-20 blind rivet nuts, furnished
by others .
Concealed electrical conduit and concealed
switch or sensor wires should be pulled to
the frame before proceeding .

Technical Data

Input power:
Power consumption:
Circuit breaker:
Power supply:
Door width:
Door weight:
Door opening angle:
Hold open time:
4
D6001DE-R Double Unit Series (Double Egress) Power Operator
Mounting Hardware
Backplate:
14 x 1-1/2 Flat Head Self Drilling Screw
Backplate:
1/4-20 x 1 Flat Head Machine Screw
Backplate:
1/4-20 x 5/8 Flat Head Machine Screw
Track:
Sex Nut and Bolt (SNB)
(optional)
120VAC, 60Hz
.9 amps
3 amps
24 V DC, max . 2 .2 amp .
36" - 48" (91-122 cm)
100-250 lb . (43-113 kg)
up to 110° with reveal of 3" (7 .6 cm) max
0-30 seconds (A .D .A . 5 seconds min .)
Indefinite for optional Infinite Hold Open
Fasteners for Frame:
1/4-20 Machine screws for
hollow metal and aluminum .
No . 14 x 2-3/4" (70mm) long
sheet metal screws for wood .
Hollow Metal Door Frame Reinforcing
Frame Material
12 Ga.
.105
(2 .66)
14 Ga.
.075
(1 .90)
16 Ga.
.060
(1 .52)
18 Ga.
.048
(1 .21)
Door or Frame
Wood
Metal
Hollow Metal
Aluminum or Wood
Notes:
Copyright © 2019-2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Templating based on 1/8" gap
between door and frame.
Reinforcing
Recommended
Min . Required
12 Ga.
.105
(2 .66)
10 Ga.
.134
(3 .41)
10 Ga.
.134
(3 .41)
8 Ga.
.164
(4 .18)
Drill
3/16" (4 .76mm)
Drill #7 ( .201 dia . or 5 .10mm)
Tap 1/4-20
9/32" (7 .00mm) thru
3/8" (9 .50mm) door face opposite to closer
3/8" (9 .50mm) thru
Permanent wiring is to be implemented as
required by local codes .
Activation devices: push plates, access control,
mats, touchless wall switches, etc .
Maximum wire size is:
12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
mounted on inside of end cap .
14AWG at all other terminals
Rate of operation shall not exceed 300 cycles of
opening and closing per hour .
80-9360-1035-020 Rev 3 03/20
Frame
Door
1/8"
(3)
18 Ga.
.048
(1 .21)
12 Ga.
.105
(2 .66)
12 Ga.
.105
(2 .66)
10 Ga.
.134
(3 .41)

Hide quick links:

Advertisement

Table of Contents
loading