Custom Zones Reports - Pima FORCE Installation Manual

Advanced security system
Hide thumbs Also See for FORCE:
Table of Contents

Advertisement

b. A user un-bypass a zone
Bypass Limit
c.
3.
Following are several points regarding the
zone restore
A
o
When siren time elapses, the zone status is checked and if it has already been closed,
the report is generated.
If the zone is not set to trigger the sirens, the report is sent as soon as the zone is
o
closed.
If a zone had triggered the alarm and was meanwhile closed, the report will be
o
generated as the alarm system is disarmed.
In partitioned system, a
o
allocated to, is disarmed.
Reporting Codes
The
Parameter
Details
 Zones
For each zone, set codes for the following events:
Fault+Restore, Bypass+Restore
 Arm/Disarm-
For each user, set event codes for
User
scroll between users.
 Arm/Disarm-
Set codes for
Other
 Faults
Set event and restore codes for the following events:
1)
2)
3)
 Alarms and
Set event and restore codes for the following events:
Others
1)
2)
8.1.3

Custom Zones Reports

System Configuration
Set the ContactID (alarm and restore) codes, and SIA's alarm and restore codes for the custom
zones. Custom zones are based on modified zone types that allow alarm reporting with any
ContactID or SIA code (other than the original zone type - Burglary, Panic, etc.).
Below is a list of more frequently used ContactID and SIA events, which can be used with the
custom zones.
Event
Gas detected
Refrigeration
Loss of heat
Water Leakage
Low bottled gas level
High temp
time elapses
report is generated when an alarmed zone is closed and rearms itself.
zone restore
menu includes the following sub-menus:
Arming
and
AC Loss, Low Battery, Power Loss, Detector's Voltage Failure,
Power:
Fuse, Peripheral's Power Fault
Communication Fault, Telephone Line Fault, Cellular
Communication:
Fault, Network Fault
External Siren Fault, Internal Siren Fault
Sirens:
Panic
Fire
and
alarms,
Tampers: Tamper 1-2
CMS & Communications
ContactID
SIA
151
GT
152
ZA
153
ZA
154
WA
157
GA
158
KA
Chap. 8: CMS & Communications
zone restore
reporting:
report is generated, only when the partition it's
. Press # or * to scroll between zones.
Arming
and
Disarming
events, in any way other than by users.
.
.
Technician On-site
Peripherals
and
Monitoring Stations
Alarm+Restore,
Disarming
. Press # or * to
.
, Invalid Code, Test.
' Alarm and Restore codes.
Custom Zones Reports
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents