Chap. 6 Zones; Zone Settings - Pima FORCE Installation Manual

Advanced security system
Hide thumbs Also See for FORCE:
Table of Contents

Advertisement

Force Security System - Installation Guide
Chap. 6
Zones
The
menu includes the following sub-menus:
1)
 Zone Settings. See below.
2)
 Zone Type Settings. See section 6.2, on page 29.
3)
 Copy Zones. See section 6.3, on page 30.
4)
 Partitions Names. See section 6.4, on page 30.
6.1

Zone Settings

System Configuration
Press * or # to select a zone.
1)
Type: select the zone type from the list. See the list below.
2)
Name: user text, up to 28 characters.
3)
Delay/24H: select from the following options:
Parameter
Instant
Entry Delay #1-2
Delay Follower
24 Hour
4)
Attributes: select from the following list:
Parameter
 Disabled
 Normally Open
 Allocated to
Home 1-4
 EOL Supervision
 Chime Zone
 Roller Blinds
5)
False Alarms: select from the list that follows (
Parameter
 Double Knock
Cross Zoning
7
Depending on the defined number of resistors. See Chap. 11, on page 42.
28
Zones
Zones
Zone Settings
Description
Opening this zone while the system is armed will trigger the alarm instantly
Opening this zone while the system is armed will trigger the alarm only
after this delay elapses, unless the system is meanwhile disarmed.
Opening this zone while the system is armed will not trigger the alarm as
long as the entry delay has not expired. If the delay elapses and the zone
is still open, the alarm will be set off.
This zone is constantly armed, regardless of the system state of arming.
In use mostly with smoke detectors and panic keys.
Description
The zone is permanently inactive.
Selected: Normally Open zone
Unselected: Normally Close zone
Home
Select to which
Multiple selection is allowed.
Select if the zone will be supervised for cut and/or short
This zone will trigger the keypad buzzer, whenever it is opened while
the system is disarmed. Also triggered is the
programmed output type.
Select to adjust the zone's sensitivity to roller blinds.
Description
This zone will trigger the alarm only if two pulses are detected during
Double Knock
the
This zone will trigger the alarm when opened, only if other cross zone is
opened too, during the
partial arming mode this zone will be allocated to.
Inactive
is also an option).
time (see Chap. 10, on page 39).
Cross Zoning
time (see Chap. 10, on page 39).
7
.
Chime Activation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents