Force Security System - Installation Guide
2.8
Connecting sirens
The Sirens inputs are for DC sirens only.
1.
Connect the external siren to the SIREN Ext.
terminals
2.
Connect the internal siren to the SIREN Int.
terminals
3.
For EOL loop supervision, connect a 2K resistor
between the two siren wires, close or inside the
siren's enclosure.
2.9
Connecting zones and outputs expanders
PIMA's product line includes zone and output expanders. All expanders interface with the BUS.
Following is the expander's list:
ZEL508
Local 8-zone expander. The expander is installed beside the control panel and is
connected using a special 4-wire cable.
ZEX508
Remote 8-zone expander with one relay output
ZEX516
Remote 16-zone expander with two relay outputs
OEX508
Remote 8-relay outputs expander
2.9.1
Interfacing with the BUS
12
Control Panel's
FORCE BUS Terminals
Keypad
Max. BUS
length: 500m
Figure 10. Connecting peripherals over the BUS
External
Internal
Siren
Siren