Chap. 7 Outputs; Onboard - Pima FORCE Installation Manual

Advanced security system
Hide thumbs Also See for FORCE:
Table of Contents

Advertisement

Chap. 7
Outputs
The
menu includes the following sub-menus:
1)
 Onboard Outputs: see below.
2)
 Zone Expanders: set the 8-zone and 16-zone expanders (ZEX508/516). There are up to
16 available outputs, depending on the overall number of expanders. See section 7.17.2.
3)
 Outputs Expander: up to 32 relay outputs can be set in outputs expanders (OEX508, 8
outputs per expander). See section 7.3.
7.1

Onboard

System Configuration
Onboard
The
menu includes the following sub-menus:
1)
 External Siren
2)
 Internal Siren
3)
 Relay
4)
 On/Off
5)
 Alarm
Both the external and internal siren outputs have the following features:
They supply high current
They can only trigger DC sirens
They can be triggered separately
Warning: the sirens outputs will be triggered, only if you don't change the
default sirens programmed output types that triggers them.
Each output screen has the following parameters:
Parameter
Details
Output Type
The programmed output type that will trigger the output. For example:
Burglary, Panic, Key in Away/Home 1-4.
For the complete list of the output types see Appendix C., on page 50.
 Positive
Set the output's polarity:
Polarity
ON/OFF, Alarm (Open Collector)
Relay
Outputs
Outputs
Onboard
Selected: the output is normally switched to ground; disconnected
when activated.
Unselected: the output is normally disconnected; switched to ground
when activated.
Selected: the C and NC terminals are normally shorted; C and NO
terminals are shorted when activated.
Unselected: the C and NO terminals are normally shorted; C and NC
terminals are shorted when activated.
Chap. 7: Outputs
31