Parameter
Partition Allocation
Soak Test Mode
6.2
Zone Types Settings
System Configuration
Zone Type
Burglary, Panic,
Silent Panic, Fire,
Duress, Medical,
Anti-Mask, Shock
Sensor, Key Switch
Modes, Custom Zone
Types
Key Switch Types
Custom Zone Types
6.2.1
Attributes
System Configuration
The zone type attributes are listed in the table below:
Attribute
Trigger Sirens
Ext. Siren at
Disarm
Reports at
Disarm
Auto-bypass
Different Siren
Tone
Description
Select the zone's partitions. The selected numbers will stay on and
not flash.
Select to put the zone in test mode for up to one week. See Chap. 10,
on page 39 for details.
Zones
Zone Types Settings
Attributes
1)
Sensitivity: set the zone sensitivity in milliseconds. Range:
1-3000, default: 800.
Sensitivity is the time period between opening the zone (relay),
and triggering the alarm. Closing the relay for one second resets
the zone.
2)
Attributes: see below.
3)
Audible Notification: select from the list:
Alarm tone: when calling the contacts, hi-lo alarm will be
sounded.
Key Switch in Away/Home 1-4: select the key type and set its
sensitivity (see above).
4)
Custom Zone Type 1-5: see the other zone types above, and in
addition:
1)
Trigger & Report: select a standard zone type (Burglary,
Panic, Etc.) to be used for reporting the CMS and triggering
outputs, or
can use it to trigger outputs to activate/deactivate special
devices such as pumps and heaters).
2)
Name: user text, up to 16 characters.
Zones
Zone Types Settings
When selected...
External
Internal Siren
The
and
triggered in alarm, and activate the sirens (by default. See Section 7.1, on
page 31 for a warning).
External Siren
The
programmed output type will be triggered in alarm,
and activate the external siren, even while the FORCE is at disarm.
Reports to the CMS will be sent, even while the FORCE is at disarm.
If this zone triggers the alarm 3 times while the system is armed, the
zone is automatically bypassed (a
the system/partition is disarmed, or until the
elapses. See Chap. 10, on page 39.
A different tone will be sounded when this zone triggers the alarm
Custom Type
. If you select
Attributes
programmed output types will be
Zone Bypass
Auto-bypass Limit
Chap. 6: Zones
Custom Type
you
report is generated) until
time
29