Pima HUNTER-PRO RSA User Manual

Pima HUNTER-PRO RSA User Manual

Hunter-pro rsa intruder alarm system lcd keypads

Advertisement

Quick Links

HUNTER-PRO RSA
Intruder Alarm System
LCD Keypads User Guide
PIMA Electronic Systems Ltd.
5 Hatzoref Street, Holon 58856, Israel
℡ +972-3-5587722
+972-3-5500442
support@pima-alarms.com
http://www.pima-alarms.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HUNTER-PRO RSA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pima HUNTER-PRO RSA

  • Page 1 HUNTER-PRO RSA Intruder Alarm System LCD Keypads User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel ℡ +972-3-5587722 +972-3-5500442 support@pima-alarms.com http://www.pima-alarms.com...
  • Page 2 PIMA’s prior written consent is granted. All efforts have been made to ensure that the content of this manual is accurate. Pima retains the right to modify this manual or any part thereof, from time to time, without serving any prior notice of such modification.
  • Page 3: Table Of Contents

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads TABLE OF CONTENTS CH. 1: INTRODUCTION ...............4 Main Features HUNTER-PRO RSA ..........5 Signs and Abbreviations Key ............6 CH. 2: KEYPADS ................7 Display Screen ................8 Keys Function................10 Entering User Menu ..............11 CH.
  • Page 4: Ch. 1: Introduction

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads CH. 1: INTRODUCTION Congratulations on your purchase of the HUNTER-PRO RSA Intruder Alarm System! Much care has been taken in developing the HUNTER-PRO RSA Intruder alarm system, which will provide you with unprecedented peace of mind.
  • Page 5: Main Features Hunter-Pro Rsa

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 1.1 Main Features HUNTER-PRO RSA 9 zones in control panel Zone doubling for control panel on-board zones (total 16 zones) Expanded up to 32 zones with wireless add-on, local, and remote bus...
  • Page 6: Signs And Abbreviations Key

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 1.2 Signs and Abbreviations Key Regular key press Long key press, until confirmation beep is heard Press this key at any programming stage in order to return to root screen...
  • Page 7: Ch. 2: Keypads

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads CH. 2: KEYPADS HUNTER-PRO RSA works with PIMA’s LCD keypads: RXN-400 and RXN-410, especially designed for maximum simplicity, durability and decorative design. The keypad is used for arming, disarming and programming the system as well as displaying time and date, system status information, events and defaults, memory log and more.
  • Page 8: Display Screen

    The lower line displays data regarding the system, such as events, faults and zone status. The user can choose between two display types: scrolling (fast zone display) and PIMA display. See section 4.12 on page 34 how to change displays. 2.1.1 PIMA User-Friendly Display...
  • Page 9 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Shortcut zone (zone is shortcut) Failed zone (disconnected)/Tamper event (in a wireless detector) Low battery in wireless detector Supervision signal: Wireless detector did nor report test to system Zone is in Soak test 2.1.2 Scrolling...
  • Page 10: Keys Function

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 2.2 Keys Function Operating and programming the system commences by first entering the Master Code and then pressing any further required keys. However, a number of keys enable certain actions by a single long press, without the Master Code:...
  • Page 11: Entering User Menu

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Programming key Display system’s name and version 2.3 Entering User Menu In order to program and change data in the user level, you must first enter the User Menu. User Menu can be fully accessed by the system administrator (owner) when using the Master Code.
  • Page 12: Ch. 3: Arming & Disarming The System

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads CH. 3: ARMING & DISARMING THE SYSTEM The system can be armed and disarmed using one of four methods: Keypad Remote control or keyfob Automatically (arming only) Remotely via touchtone telephone, COMAX software, Internet, and GSM As a rule, the system should be armed ONLY when all zones (but those on the exit route) are closed and there are no faults (e.g., battery, mains,...
  • Page 13: Arming With Master Code

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads After entering one of these codes, the green control LED shall begins to blink, a beep will be heard from the keypad, and the display will show the exit delay message: Arming...
  • Page 14: Fast Arming

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 3.1.4 Arming the System to HOME Mode Arming to “HOME 1”: Short Code User Code Arming to “HOME 2”: Short Code User Code NOTE: After long pressing the HOME key (i.e.
  • Page 15: Alarm System

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 3.1.7 Arming with Keyfob VISONIC’s keyfob is designed Disarming Indication LED: for PIMA’s IO-W wireless lit when keyfob receiver. The keyfob remote buttons pressed Relay control includes 4 buttons...
  • Page 16: Arming/Disarming With Key

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 3.1.7.2 Canceling Keyfob for User … User Menu the first user Master Code Choose 1,2... 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...
  • Page 17: Remote Control Via Touch-Tone Phone

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads NOTE: If the system does not turn to Disarm state, make sure that the time is included in the preset time frame that enables disarming the system (see section 4.1.2.5 in “Programming User Codes”)
  • Page 18 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads NOTES: The system will not identify commands from the telephone while sounding the confirmation tone. It is important to wait until to confirmation tone is over before pressing the telephone keys that control the system.
  • Page 19 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads General Control panel Output card Expanders 00 - Disable 11 - Siren 21 - Output no.1 31 - Expander siren and no.1 12 - Siren 22 - Output no.2...
  • Page 20: Ch. 4: Programming & Operation

    IMPORTANT! Pay attention that HUNTER-PRO RSA has a code-control feature that does not allow entering identical codes. For example, if one of the user (or master) codes is programmed as 1010, any attempt to program a new code as 1010 or starting with 1010 (e.g., 10101, 10102, 10103, etc.) will display an error message.
  • Page 21: Programming Users

    HUNTER-PRO RSA holds up to 24 different User Codes, 4 to 6 digits each. See “Entering User Menu” on page 11 for a description on how to access the User Menu with User Code.
  • Page 22 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.1.2.1 Changing (adding new) User Code User 1 ENTER/NEXT/END (Use to reach designated user / press user’s Entr/Change Code User 1 ENTER/NEXT/END ****** (4-6) number) User Code (4 to 6 digits) 4.1.2.2...
  • Page 23 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Pressing the key: saves the data Pressing the key clears the display NOTE: User Name includes up to 8 characters (letters or digits) Each arming/disarming will enter the memory along with the user name, date and time (see section “Memory Display”...
  • Page 24 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.1.2.4 Modifying User Access User 1 User Access ENTER/NEXT/END ENTER/NEXT/END UTCMBKA +++----- Set user’s access NOTE: To scroll on Access Bar, use keys. Marking a “+” under a parameter’s letter authorizes the user to program this parameter.
  • Page 25 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.1.2.6 Programming User Partitions User 1 Partitioning ENTER/NEXT/END ENTER/NEXT/END Part. For User1 ++++++++++++++++ Set user’s partitions This feature links a user to a partition(s). When creating subsystems, there is also a keypad linked to each split (done by the technician), therefore the user can only arm/disarm and view the linked partition using the designated keypad.
  • Page 26: Programming Time And Date

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.1.4 Programming Short Code This two-digit code can only arm the system. Master Code/ Enabled User Code/ long press + User Code Short Code ENTER/NEXT/END Enter new code (2 digits)
  • Page 27: Automatic Arming

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Master Code/ Enabled User Code/ long press + User Code The following screen will appear: Hour Month Year 00:00 Enter time Enter date NOTES: Enter time in 24:00 (HH:MM) format and date in day/month/year format The system will not accept meaningless data, such as 25:25 time.
  • Page 28 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads After the ‘warning countdown’ is over, the system will begin regular arming process, including exit delay and beeps from the keypad. 4.3.1 Programming Auto-Arming at Preset time Master Code/ Enabled User Code/...
  • Page 29: Private Dialer Telephone Numbers

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads “-“ to “+” and vise versa, and keys to scroll back/forth between partitions. NOTE: Marking “+” above partition number will activate that partition with feature. “-“ will not. Press to save programming and move to the next screen.
  • Page 30: Chime

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Master Code/ Enabled User Code/ long press + User Code Enter Telephone number no. 1 Enter telephone number no. 2 Enter Telephone number no.3 Enter Telephone number no.4 to exit.
  • Page 31: Panic

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.5.2 Temporary Cancellation of Chime Temporary cancellation of chime is valid for all zones: Press and hold the key to enable/disable the chime feature according to the state in which the system is in; the display will show one of the...
  • Page 32: Canceling Keypad Buzzer

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.9 Canceling Keypad Buzzer The keypad produces a variety of sounds at times of pressing a key, confirming a long-press, during countdown, disarming the system, and so Simultaneously pressing the keys activates/cancels this feature.
  • Page 33: Memory Log

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.11 Memory Log The system memorizes up to past 410 events and operations in a chronological order. IMPORTANT! The last 128 events are non-volatile. 4.11.1 Accessing Memory Log Manually...
  • Page 34: System Display

    F a u l t 4.12 System Display HUNTER-PRO RSA has two system status displays, and seven types of zone status display. The two system status displays are: Fast Display: All the zones and their status appear in a single screen Scrolling Display: A detailed description of the zones and their status, each zone in a different screen, and automatically appearing one after the other.
  • Page 35: Zone Status Display

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 4.12.2 Scrolling Zone Display Master Code/ Enabled User Code/ long press + User Code display changes to Scrolling Display. 4.12.3 Zone Status Display Master Code/ Enabled User Code/ long press + User Code...
  • Page 36: Ch. 5: Troubleshooting

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads CH. 5: TROUBLESHOOTING NOTE: If more then one failure is detected, the display will scroll the failure list one after the other. If more than one keypad is connected to the HUNTER-PRO, and you are...
  • Page 37 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Low Voltage Appears before the back-up battery is completely discharged, usually after a prolonged power failure. Follow instruction for low battery failure. Zone Fault One of the protected zones is faulty. Call the technician.
  • Page 38: Zones Names

    HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 5.1 Zones Names Zone Partition Zone Name...
  • Page 39 HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads Zone Partition Zone Name...

Table of Contents