Radio - Pima FORCE Installation Manual

Advanced security system
Hide thumbs Also See for FORCE:
Table of Contents

Advertisement

Force Security System - Installation Guide
Parameter
Details
2)
3)
Periodic Test
Set a time of the day to send a test report to the CMS. This report is sent in
addition to the test report interval (next).
Test Interval
Set an interval in hours to send a test report to the CMS. This report is sent
in addition to the periodic test report.
Number of Dials Set the number of dials and redials that if fail (no ACK is received), a
communication fault is reported.
 Primary Path Select if the telephone is the primary path for reporting the CMS.
4)
 GSM-Voice: see the Telephone (PSTN) menu above.
5)
 Network (Ethernet): in addition to the above Telephone (PSTN) parameters, the network
has the following:
Parameter
Details
 Network
IP/URL 1-2: enter up to two IP addresses of the CMS, or a URL (web
Addresses
address).
Port 1-2: enter the port no.
Supervision
Set supervision (test) report interval. The report
is designated to the IP receiver at the CMS.
6)
 GPRS-IP: see Network (Ethernet) above.
Event Reporting
System Configuration
Select the events to report to the CMS (e.g. Burglary Alarm, Tamper Alarm, Invalid Code).
8.1.2

Radio

System Configuration
See section 8.1.1 above for details on the parameters, except those on the next table:
Parameter
Details
Format
Set the radio format. Obtain it from the CMS.
 Report Codes See below.
Transmissions
Set the number of transmissions and retransmissions
No.
per report.
Frames Per
Set the number of frames per single transmission.
Trans.
Reporting Codes
Set the radio reporting codes for alarms and other events, as well as the restore codes. Note
the following:
1.
The codes apply only for some radio protocols. Consult the CMS before setting them.
2.
A zone is restored in the following conditions:
a. The alarm system/partition is disarmed (or the first partition, if the zone is allocated to
more than one).
34
 Kissoff Wait: how long to wait for a Kissoff message, before
resending the report. Change only if necessary, for example if there are
delays in the communication. Range: 1-5000 milliseconds.
 ACK Frequency: select between Lo-Hi, 1400, 2300, and SIA.
CMS & Communications
CMS & Communications
Monitoring Stations
Monitoring Stations
Default
Range
5 min
0 (not reporting)-
59:59 mm:ss
CMS 1-2
Event Reporting
Radio
Default
-
-
5
10
Range
1-16
1-16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents