5.2 Logging in to the unit after powering it on for the first
time
When you start the unit for the first time, you need to log in using the default user information shown in the table
below and then change the password.
Table 5‒1: Default user information
User name
edgeadm
Hitachi1
This password is only valid for the first login.
#:
To ensure security, the password change function starts immediately after the first login.
Note that, when repair work is performed, the operating system might be reinstalled. In that case, the password
and other settings will be initialized.
Set a new password for edgeadm. Use the new password for the subsequent login.
Login: edgeadm
Password: Hitachi1
You are required to change your password immediately (root enforced)
Changing password for edgeadm.
(current) UNIX password: <- Enter "Hitachi1" for the password.
New password: <- Enter the new password.
Retype new password: <- Enter the new password again for the confirmation
In addition, consider creating a user account for each person who operates the unit, such as for each maintenance
worker, rather than allowing edgeadm to be shared by multiple users. Setting an account for each user makes it easier
to identify the cause of a security incident.
For details about how to add or delete a user or change the password, see 6. Managing User Accounts.
After the password is set, the software license is displayed. Verify the displayed information, enter yes, and then
press the Enter key.
Depending on the software installed on the product, multiple licenses might be displayed. If you verify all the licenses
and then enter yes, you will be logged in to the unit.