8. Troubleshooting
### Started a compression of system information. ###
### Successfully completed.(20150801181021-eclog.tgz) ##
$
5. Use the ls command to check the size of the maintenance information file.
$ ls /tmp
-rw-r--r-- 1 0
-rw-r--r-- 1 0
6. Log out.
Log out from the target unit.
$ exit
7. Use the scp command to transfer the file to the maintenance PC.
Log in by using any user ID.
The following shows an example of when the target unit is 192.168.11.1. For the file name, enter the file
name displayed in step 4 (enter the bold underlined parts).
$ scp user-name@192.168.11.1:/tmp/20150801181021-eclog.* .
Password:password
8. Check the size of the transferred file.
Confirm that the size of the file saved in the maintenance PC is the same as the file at the acquisition source
(check the bold underlined parts).
If the maintenance PC is Linux:
$ ls -l 20150801181021-eclog.list
-rw-r--r-- 1 root root
$ ls -l 20150801181021-eclog.tgz
-rw-r--r-- 1 root root 115753706 Aug
If the maintenance PC is Windows:
> dir
directory-under-W:\Users\hoge\eclogsave_dir
2015/08/01
2015/08/01
8.2.3 Collecting maintenance information in configuration No. 3
Save maintenance information in external media connected to the unit. Before you start this operation, perform the
following:
• Disconnect the unit from the external system.
• Create partitions in the external media, and then format them with EXT4.
The backup data save area in the external media must be formatted with EXT4.
• Change the OS operation mode to maintenance mode.
150
0
873 Aug
0
115753706 Aug
873 Aug
18:10
873
18:10 115,753,706
20150801181021-eclog.tgz
1 18:10 20150801181021-eclog.list
1 18:10 20150801181021-eclog.tgz
1 18:10 20150801181021-eclog.list
1 18:10 20150801181021-eclog.tgz
20150801181021-eclog.list