Periodic Inspection Items - Hitachi CE50-10 Instruction Manual

Table of Contents

Advertisement

7.3 Periodic inspection items
CAUTION
Do not disassemble the unit during inspection or cleaning. The unit has a sealed structure and does not require internal
inspection or cleaning. When the cover is removed, do not touch internal parts, as doing so might cause a burn injury,
damage to internal parts, or unit failure.
NOTICE
• Do not hot swap USB equipment or cables with the unit. Hot swapping might cause the unit to malfunction or
stop.
• Before moving the unit, shut down the OS, turn off the MAIN POWER switch, and then remove the power cable
plug from the outlet. Not following this procedure might result in unit failure.
• When carrying or transporting the unit, it is recommended that you use the packing materials in which the unit
was packaged for delivery. If such packing materials are not available or are damaged, carefully pack the unit in a
way that protects it from shock, vibration, and electrostatic discharges.
• Moving or transporting a unit that is installed in a cubicle or rack with casters might subject it to excessive
vibration or physical impact, resulting in failure of the unit. Select or design a cubicle or rack that meets the
installation conditions. Similarly, make sure that the unit is not subject to vibration or physical impact when you
move, carry, or transport it.
• Table 7‒5: Periodic inspection items shows periodic inspection items. Hitachi is responsible for performing
periodic inspection under maintenance contract. Only Hitachi staff and officially-trained personnel are permitted
to perform periodic inspection.
Include the inspection in the system operation schedule.
Table 7‒5: Periodic inspection items
Collecting and checking logging information
Checking and cleaning the parts
• Checking and cleaning inside and outside of the cubicle (each unit)
• Checking connectors and screws for looseness
• Checking operation of lamps
• Checking operation of switches and buzzers
Checking operations and functions
• Checking the set time
• Checking operation by using a test program
• Checking operation of application programs
Periodically replacing life-limited parts
Item
7. Maintaining the CE50-10
Frequency
Time required
Once a year
10 minutes
Once a year
30 minutes
Once a year
60 minutes
See Table 7‒6: Life-limited parts.
139

Advertisement

Table of Contents
loading