5. Stop the unit.
Run the shutdown command to stop the unit, and then turn off the power.
$ shutdown -h 0
6. Unplug or connect the LAN cable.
Disconnect the cable connecting to the maintenance PC if it has been connected during maintenance work.
Connect the LAN cables to the remainder of the system, which has been temporary disconnected during
maintenance work.
7. Turn on the power to the unit.
Start the unit.
8. Log in to the unit.
login: edgeadm
Password: *******
9. Check the current OS operation mode.
Run the showecmode command to check the current OS operation mode. Confirm that Normal mode is
displayed for both Current and Next (see the bold underlined parts).
$ sudo showecmode
Current
: Normal mode
Next
: Normal mode
$
5. Configuring Software Environment