ry!hy(rY1.HY): Relay 1 Hysteresis
ry!hy
0000
The function is to avoid the relay on and
off frequently, when the display value is
)0
swing near by the set point. The typical
5000
application is to control a compressor.
User can set a band to prevent the relay
on and off frequently.
ry!rd
ry!rd (rY1.rd): Relay 1 energized
delay time
)0)0
)0)0
(5(9
ry!fd
ry!fd (rY1.Fd): Relay 1 de-energized
delay time
)0)0
)0)0
(5(9
ry@md
ry@md(rY2.Md): Relay 2 energized
mode
hi
hi
hIhld
ry@hy(rY2.HY): Relay 2 Hysteresis
ry@hy
00)0
)0
50)0
ry@rd (rY2.rd): Relay 2 energized
ry@rd
delay time
)0)0
)0)0
(5(9
ry@fd (rY2.Fd): Relay 2 de-energized
ry@fd
delay time
)0)0
)0)0
(5(9
Energized / De-energized
Delay & Hysteresis
[ry_.sp]
Hi Setting
[ry_.rd]
Relay
Energized
MW-5 Operating Manual 2012-07-19
Settable range: 0~19999 digits
Shift
[ry_.hy]
Hysteresis
[ry_.fd]
ON
Settable range:
0:00.0~9(M):59.9(S)
Shift
Settable range:
0:00.0~9(M):59.9(S)
Shift
....as same as Relay 1 Energized
Mode...
Programmable:
off(off) /
hi(Hi) / hIhld(Hi.HLd) /
lOhld(Lo.HLd) /
&
Settable range: 0~19999 digits
Shift
Settable range:
0:00.0~9(M):59.9(S)
Shift
Settable range:
0:00.0~9(M):59.9(S)
Shift
Up
Down
Enter
Up
Down
Enter
Up
Down
Enter
lo(Lo) /
do(DO)
Selection
Enter
Up
Down
Enter
Up
Down
Enter
Up
Down
Enter
23 / 36