Principle Of Operation Of Inc/Dec Commands - btsr MULTIFEEDER Operating Manual

Yarn control system
Table of Contents

Advertisement

Technical Data and Installation

Principle of operation of INC/DEC commands

2
The KTF/PW4 power supply has an analogue exclusion input (
connectable to the machine inverter input (e.g. on MATEC machines).
The analogue exclusion input allows to exclude the MULTIFEEDER devices
when the machine drops under a determined number of revs/min, i.e. when it
is in the stop phase.
The KTF/PW4 power supply comes with the analogue input already calibrated
for correct operation; however you can change the triggering point of
MULTIFEEDER exclusion, by adjusting the trimmer (T).
3
Connect the 24VAC supply terminals to the output of TRF24 transformer.
4
Connect the
terminal to the machine ground potential.
5
Connect the STOP output of both KTF/PW4 groups to the machine STOP
input.
6
Connect (+ INC) and (+ DEC) terminals to the thread guide common positive
or solenoid valves of the machine.
7
Connect (- INC ) and (- DEC) terminals to a pair of thread guide
programmable outputs or solenoid valves, or use the outputs provided by
BTSR for MULTIFEEDER devices.
Activate the programmable INC/DEC outputs simultaneously with the thread
guide of yarn under control and keep the commands active for all the yarn
processing time, then deactivate the programmable INC/DEC outputs
simultaneously with the thread guide of yarn.
8
Set the jumper to position
When the INC/DEC commands are active, the MULTIFEEDER device operates
with the tension value set in
alarm will be active.
TENSION
When, on the contrary, the INC/DEC commands are deactivated, the
MULTIFEEDER device operates with the tension value set in
function of P2 menu and the
To gradually adjust the value of tension set in
once the INC/DEC command have been activated, you will have to generate INC
(increment) or DEC (decrement) pulses.
For each INC or DEC pulse, the
Incremented or Decremented by the amount set in
variable of P1 menu).
For further information on P1 ÷ P4 menu's programmable functions, please
refer to Chapter 3 –Operation.
MULTIFEEDER
.
function of P1 menu, and the
MAIN TENSION
will be deactivated.
ERROR TENSION
MAIN TENSION
value will be respectively
MAIN TENSION
)
EXIT TENSION
function of P1 menu,
-
function (last
INC
DEC TENSION
ERROR
- 2.5 -