Page 1
SMART CLEARER & ISSC. YARN CONTROL SYSTEM Operating Manual ENGLISH Rev. 3.0 – July 2003...
Page 2
Copyright 2003 - BTSR – All rights reserved. This manual is intended for the users of the SMART CLEARER system. It is suggested to carefully read the instructions described in this manual before making the connections and use the system.
Interface specification ...............................3.5 Interpretation of the signalling lights located on the sensors .................3.6 Parameters that affect the sensor detection features ....................3.7 Preliminary operations for using the SMART CLEARER terminal..............3.11 Operating Sequences .............................3.12 Machine Start Procedure............................3.13 Preliminary Instructions for the Correct Use of ISSC.. Sensors..............3.13 Restart after an Alarm Condition on a Single Position ..................3.13...
Page 4
SENSOR TEST Sensors Test ........................3.30 COM TEST Testing the Efficiency Rate over the Communications Line between the SMART CLEARER Terminal and Sensors ..............3.31 VERS-UPG Software Version Test and Update...................3.32 Creating a New Article ......................3.33 SPEED - Creating a New Article - Machine collection speed ........3.35 NEP - Creating a New Article - Characteristics of the Nep defect ........3.36...
Appendix B – Electrical Connections include a connection diagram showing the use of the SMART CLEARER system and ISSC.. sensors in a general purpose application environment. Symbols used Highlights notes, warnings and subjects to which the attention of the reader should be directed.
Page 6
CTR = Control CAL-aM Manual (M) or Automatic (A) aM = Manual calibration mode CAL-Am Am = Automatic Alternative items: Within the description of configuration/programming procedures the alternative screen shots are shown with this bracket symbol. - I.2 - SMART CLEARER...
Special Features of SMART CLEARER system The SMART CLEARER system has a set of unique features which make it a true microcomputer dedicated to the yarn quality control. SMART CLEARER is a fully parametric system; this means that for each type of defect the use can freely define the desired parametric values.
The system allows connecting up to 200 yarn quality control sensors of the ISSC.. series. Easy Monitoring Besides the information shown on graphical display of SMART CLEARER, each ISSC.. sensor has a red LED that, when flashing, indicates the type of fault detected.
10° - 50 °C Installation The installation of the SMART CLEARER system depends on the type of application and on the number of sensors to be connected. When the number of sensors is limited, it is possible to connect them directly to the SMART terminal, otherwise it is necessary to use a stabilized power supply PSU 10A.
Technical data and installation Interface Connectors on SMART CLEARER Concerning all electrical systems, it is a recommended rule to ensure that the ground cable (GND) is connected to the sensor support. - 2.2 - SMART CLEARER...
Technical data and installation Connection Cables and Power Supply Devices To correctly install the SMART CLEARER system and sensors, it is necessary to use a certain number of connecting cables provided by BTSR; their length and type depend on the specific requirements and application types.
Machine Start/Stop Contact– ENABLE. For further details see “ENABLE Signal Function” page 3.5 Concerning all electrical systems, it is a recommended rule to ensure that the ground cable (GND) is connected to the sensor support. - 2.4 - SMART CLEARER...
OPERATION SMART CLEARER Terminal Features As in all SMART BTSR systems, the operation of SMART CLEARER system is controlled by just 5 membrane buttons and it is monitored by a LCD graphic display, which guides the operator through all programming and administration phases of the system, by means of straight-forward messages which can be understood clearly and immediately.
Page 14
When entering numeric data (for example the number of sensors) it allows you to decrease the numeric value of the field. If it is held down continuously the numeric field decrements more rapidly. - 3.2 - SMART CLEARER...
Page 15
P1 it is useless to press the RESET button, as the system is already in the main menu and it is not possible to select a higher level of the menu. SMART CLEARER -3.3 -...
Autocalibration (when operating in manual mode). During the automatic numbering of the sensors (flashing green LED) the Touch Light assigns to the sensor the number displayed in the Device configuration screen. Touch Light - 3.4 - SMART CLEARER...
ISSC.. device releases the STOP signal, but still maintains the Red LED signalling until the ENABLE signal is released and, after waiting for a time corresponding to DELAY CONTROL, it resumes the normal yarn control. SMART CLEARER -3.5 -...
Green LED OFF Sensor not powered. Red LED OFF Green LED FLASHING Indicates a sensor fault (e.g. Loss of stored data). Red LED FLASHING Try to reprogram the sensor. If the fault remains, replace the sensor - 3.6 - SMART CLEARER...
Page 20
(i.e. 80 90%). SPEED Is the yarn collection speed of the machine; the Minimum Defect Length values are converted into a ISSC.. sensor reaction time depending on this speed (Programmable as 1 m/min to 2000 m/min.). - 3.8 - SMART CLEARER...
Page 21
The Stop output is normally open and it is connected to ground to STOP NO: signal an alarm condition. The Stop output is normally closed (connected to ground) and it is STOP NC: opened to signal an alarm condition. SMART CLEARER -3.9 -...
Page 22
(detected by means of the enable signal), the sensor will automatically perform the calibration procedure, without the need to keep the yarn outside the sensor. If the operator does not press the touch light, the sensor will restart working with the old calibration. - 3.10 - SMART CLEARER...
Operation Preliminary operations for using the SMART CLEARER terminal Just after installation and before beginning to use the system, check that all the connectors are plugged in properly and that ISSC devices are turned on. System Power on the system and check that the graphic display shows sequentially, for a...
Operation Operating Sequences The SMART CLEARER system allows the following set of functions to be carried out: Univocal identification of each sensor by means of an automatic numbering procedure. Programming, modifying, controlling and saving the values related to the different articles, by means of a database which can manage up to 40 different articles.
DELAY CONTROL plus Auto Learning time (if any), the sensor turns on the green LED in steady way. 4) At this point the SMART CLEARER continuously monitors the sensors’ operating status, displaying the alarm conditions (if any). In case of multiple alarms, use the Next Cycle button to display the sequence of all alarm conditions.
CONTROL Function = sensor number ZZZZ = defect type (NEP, SLUB-, SLUB+, YARN-, YARN+, NOYARN) = No defects detected by sensor XX Further details about the identification of possible problems can be found on the “Troubleshooting” chapter. SMART CLEARER -3.17 -...
The number YYY is increased by 1 unit. Once all the sensors have a unique number assigned, the DEVICE CONFIG message re-appears. Press once to return to the Setup/Programming menu, or press it twice to return to the Main Menu. - 3.18 - SMART CLEARER...
Starting from Ver. 2.0 it is possible to set D_CNTR value to zero. In this case the delay will be 100 msec. If you use the SMART system in AUTO-LEARNING mode, the minimum delay should be 5 seconds. SMART CLEARER -3.19 -...
Either UNLOCK WAIT - UNLOCK PRG OK or LOCK WAIT - LOCK PRG OK will appear to indicate that the function has been correctly programmed. Press once to return to the CONFIG menu, or twice to return to the Main Menu. - 3.20 - SMART CLEARER...
= moves the cursor from XXX field to YYY field = increases the field pointed by the cursor = decreases the field pointed by the cursor Sensors before XXX and after YYY will automatically be programmed in Control mode. SMART CLEARER -3.21 -...
Page 34
Operation If you change the XXX ÷ YYY range, the SMART CLEARER terminal will automatically update the situation, thus bringing back to Control mode the sensors which are no longer included in the new range. Only one XXX ÷ YYY range may be programmed.
WAIT and ENAB - NO PRG OK or ENAB - NC WAIT and ENAB - NC PRG OK to indicate that the function has been programmed correctly. Press once to return to the CONFIG menu, or twice to return to the Main Menu. SMART CLEARER -3.23 -...
WAIT and STOP - NO PRG OK or STOP - NC WAIT and STOP - NC PRG OK to indicate that the function has been programmed correctly. Press once to return to the CONFIG menu, or twice to return to the Main Menu. - 3.24 - SMART CLEARER...
ST_Cont WAIT and ST_Cont PRG OK or ST_Puls WAIT and ST_Puls PRG OK to indicate that the function has been programmed correctly Press once to return to the CONFIG menu, or twice to return to the Main Menu. SMART CLEARER -3.25 -...
CALAuto WAIT and CALAuto PRG OK or CAL-Man WAIT and CAL-Man PRG OK to indicate that the function has been programmed correctly Press once to return to the CONFIG menu, or twice to return to the Main Menu - 3.26 - SMART CLEARER...
ABS WAIT and ABS PRG OK or REL WAIT and REL PRG OK to indicate that the function has been programmed correctly. Press once to return to the CONFIG menu, or twice to return to the Main Menu. SMART CLEARER -3.27 -...
WARNING: If you set a password (Keycode) it is necessary to enter it each time you access SETUP and WORK menu and when you want to leave the CONTROL mode. If you forget the access code it will be necessary to contact your BTSR reseller. - 3.28 - SMART CLEARER...
CONFIG menu, or twice to return to the Main Menu. If the printer is not connected correctly, the ERR-COM PRINTER message will appear. For further details, please refer to chapter al Cap. 4 “Troubleshooting”. SMART CLEARER -3.29 -...
SENSOR This function gives you the possibility to check communications between the SMART CLEARER terminal and (one by one) each of the connected sensors. In this way it is possible to check that: All sensors are correctly numbered and identified All sensors respond correctly to the terminal The same number has not been assigned to more that 1 sensor.
TEST This function allows you to check the perfect operation of the communications line between the SMART CLEARER Terminal and connected Sensors. It is advisable to run this check during the first testing phase (immediately after installation) and each time random problems occur in the system operation, which...
This function allows you to check the software version on each individual sensor, with the possibility to update the version, if needed.. The updating procedure is effective only if all the sensors have a software version ≥ 3.0 and only if strictly necessary, for instance upon indication of your BTSR distributor. Press until the TEST CONFIG menu option is displayed.
Type the name using to set the characters and use to move the cursor. If you enter a name already existing, the warning message DOUBLE NAME will be displayed. In this case press and enter a new name. SMART CLEARER -3.33 -...
Page 46
WARNING: During the configuration of SLUB-, SLUB+, YARN+, YARN- and NEP, parameters, if you press the CONTROL key, the parameter an under configuration will be disabled; to re-enable the parameter, simply press again the CONTROL key. - 3.34 - SMART CLEARER...
Set the desired speed in M/min using Press to confirm. This screen, displayed for a few seconds, indicates that the previously set speed (XXX M/min) will be assigned to the article being created. Press to select the next parameter (NEP). SMART CLEARER -3.35 -...
Page 48
Press to continue. This screen, displayed for a few seconds indicates that the Minimum Length parameter has been programmed correctly. Press to return to the Article Parameters Menu, then to select the next parameter (SLUB) - 3.36 - SMART CLEARER...
Set the Minimum Length of reduction using Press to continue. This screen, displayed for a few seconds, indicates that the Minimum Length parameter has been programmed correctly. Press to return to the Article Parameters Menu, then to select the next parameter (SLUB+). SMART CLEARER -3.37 -...
This screen, displayed for a few seconds, indicates that the Minimum Length parameter has been programmed correctly. Press to return to the Article Parameters Menu, then to select the next parameter (YARN -). - 3.38 - SMART CLEARER...
Page 51
Set the Minimum Length of the Missing Ply defect using Press to continue. This screen, displayed for a few seconds, indicates that the Minimum Length parameter has been programmed correctly. Press to return to the Article Parameters Menu, then select the next parameter (YARN +). SMART CLEARER -3.39 -...
This screen, displayed for a few seconds, indicates that the Minimum Length parameter has been programmed correctly. Length parameter has been programmed correctly. Press to return to the Article Parameters Menu, then to select the next parameter (NOYARN). - 3.40 - SMART CLEARER...
Press once to return to the Article Parameters Menu, or two times to store all parameters of the article and exit the Article Creation function. Press to save the Article into the data base. SMART CLEARER -3.41 -...
During the erase process, the OK WAIT message is displayed . BTSR TST is the Default article, and it cannot be erased! If you try to erase it a warning message NO DEFAULT appears. In this case press Reset to return to the >ERASE CONFIG screen.
WORK SCAN This function allows the display of articles which are loaded into the sensors connected to SMART CLEARER system. Press to have access to the function. The screen shows the first article loaded in the sensors connected to the SMART CLEARER system.
LOAD This function allows loading of an article (more specifically the settings of the article) on a specified range of sensors connected to the SMART CLEARER system. The sensors must have been previously declared and numbered using the CONFIG DEVICE function Press to have access to the function.
>UNLOAD SCAN screen or two times to return to Main Menu. The END UNLOAD message means that all articles have been unloaded from the sensors connected to the SMART CLEARER system. SMART CLEARER -3.45 -...
Insert the yarn into all positions and start-up the machine. (Autoset), the display of SMART CLEARER At the end of the learning procedure terminal will show the message CONTROL OK and the system will activate the CONTROL operating mode.
When the printing is completed, the REPORT xxx, yyy screen will re-appear, allowing you to select a new sensor range for report printing. In case of communication error between SMART CLEARER terminal and printer, an ERR_COM PRINTER error message will appear.
Page 60
Operation Sample report referred to four positions (001/004). - 3.48 - SMART CLEARER...
If necessary contact you BTSR distributor. attempt. If the fault is not included in the above table, please contact your local BTSR reseller, giving a detailed description of the kind of fault and the conditions in which it occurred. In the case where the...
For cleaning purposes, do not use solvent, but rather a soft cloth dampened with neutral detergent or alcohol. Repairs Any repair intervention on the SMART CLEARER terminal must be executed by specialised personnel from BTSR. Any intervention attempt by non authorised personnel, voids the warranty terms.
Troubleshooting and Maintenance Updating the Software Version on SMART Terminals The software updating on BTSR SMART terminals is a relatively easy operation. However it must be carried out following scrupulously the instructions given in this manual and using the indicated tools to avoid damaging the equipment and/or microprocessor contacts.
QUICK REFERENCE The following flow-charts show briefly the operating sequences which are required to complete all the functions available on the SMART CLEARER system. The use of the quick reference guide supposes that the user has already acquired a certain ability in handling the system, therefore there are no detailed explanations of each screen shot;...
Appendix B – Installation Example INSTALLATION EXAMPLE INSTALLATION EXAMPLE INSTALLATION EXAMPLE INSTALLATION EXAMPLE The example included in the next page shows the interconnection of devices that constitute the SMART CLEARER system. SMART CLEARER - B.1 -...
Page 80
Appendix B – Installation Example SMART CLEARER ELECTRICAL CONNECTIONS EXAMPLES Concerning all electrical systems, it is a suggested rule to ensure that the ground cable (GND) is connected to the sensor support. - B.2 - SMART CLEARER...
Page 81
DISTRIBUTOR BTSR International S.p.A. Via S. Rita 21057 OLGIATE OLONA (VA) Tel. 0331-323202 Fax 0331-323282 Internet: www/btsr.com REV.3.0 – 07/03...
Need help?
Do you have a question about the SMART CLEARER and is the answer not in the manual?
Questions and answers