Auto Media Sensor Calibration

Auto Media Sensor Calibration automatically establishes the optimum sensing values for the media
you are using.
Before calibrating, be sure the media sensor is set for the appropriate media type, also ensure
that the Printhead Carrier Assembly is latched down and the cover is closed.
To automatically calibrate the media sensor:
1. With the desired media loaded, hold the
to hold the button until the
2. Next press the
PAUSE
calculate the TOF Delta and Low values to be used.
3. Upon completion, one of the following lights will flash five times to denote the result of the auto
calibration attempt:
Light = Successful calibration. Proceed to Step 4.
STOP
Light = Unsuccessful calibration, try again. If the calibration continues to fail proceed to
ERROR
Manual Media Sensor Calibration.
If you wish to discard the changes and revert back to the previous calibration simply turn off the printer
before Step 4.
4. Now save the changes and resume
simultaneously and briefly. Wait until the
Appendix C – Paper Menu Setup
CANCEL
light turns off then release it.
STOP
button. The printer will feed approximately ten inches of media to
STOP
button while powering up the printer. Continue
by pressing the
PAUSE
light goes off.
+
buttons
CANCEL
87