SENSOR
CALIBRATION
PERFORM
CALIBRATION
ADVANCED ENTRY
PAPER SENSOR
LEVEL
REFL PAPER
LEVEL
GAP SENSOR
LEVEL
MARK SENSOR
LEVEL
EMPTY SENSOR
LEVEL
TRAN SENSOR
GAIN
REFL SENSOR
GAIN
PRINTHEAD
CLEANING
CLEAN HEAD
SCHEDULE
CLEAN HEAD
COUNTER
RESET COUNTER
CLEAN HEAD NOW
Chapter 4 – Menu System
Selects the media sensor calibration method, where:
Sets the values via internal printer calculations, as described in the STANDARD
CALIBRATION procedure.
Sets the values via manual entry (typically for hard to calibrate label stocks), as
described in the ADVANCED ENTRY CALIBRATION where:
Establishes the threshold for the paper value (0 - 255), where 170 is the default
setting.
Establishes the threshold for the reflective value (0 - 255), where 170 is the
default setting.
Establishes the threshold for the gap value (0 - 255), where 040 is the default
setting.
Establishes the threshold for the mark value (0 - 255), where 040 is the default
setting.
Establishes the threshold for the empty value (0 - 255), where 000 is the default
setting.
Establishes the sensitivity of the transmissive sensor (0 - 31), where 15 is the
default setting.
Establishes the sensitivity of the reflective sensor (0 - 31), where 15 is the
default setting.
Controls the automatic cleaning alert and function, where:
Specifies the inch (or centimeter) count at which to clean the printhead, and if
exceeded three times, declare a Head Cleaning Fault. (Note that the specified
count [0 - 200 inches] will be multiplied by one thousand, and that zero [the
default setting] will disable the function.)
Indicates the number of inches (or centimeters) since a cleaning was last
initiated.
Resets the Clean Head Counter to zero to restart the Clean Head Schedule.
Initiates the cleaning process and resets the Clean Head Counter.