iLux
Lighting System
• iLux
™
50
Lighting System: CLS/CLSI-C6 & CLS/CLSI-C6M
Crestron CLS/CLSI-C6 & CLS/CLSI-C6M
Function name
Open Shades Momentary (All, Group 1-6)
Behavior
Specified shades will move toward the Open position for as long as the
button is pressed. Movement will stop when button is released.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
Shade commands with "All" parameter will only affect all the shade
groups connected to the given CLS-C6 module. They will not pass from
one CLS-C6 module to the other (either when directly connected or
when linked through Cresnet system). To accomplish this function for all
shades in a multi-unit system, use SIMPL programming.
Function name
Close Shades Momentary (All, Group 1-6)
Behavior
Specified shades will move toward the Closed position for as long as
the button is pressed. Movement will stop when button is released.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
Shade commands with "All" parameter will only affect all the shade
groups connected to the given CLS-C6 module. They will not pass from
one CLS-C6 module to the other (either when directly connected or
when linked through Cresnet system). To accomplish this function for all
shades in a multi-unit system, use SIMPL programming.
Function name
Jog Shades Open (All, Group 1-6)
Behavior
Specified shades will move toward the Open position for the specified
jog time, and then stop.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
Jog time defaults to 0.05 sec. Other values can be set in iLux Designer.
Shade commands with "All" parameter will only affect all the shade
groups connected to the given CLS-C6 module. They will not pass from
one CLS-C6 module to the other (either when directly connected or
when linked through Cresnet system). To accomplish this function for all
shades in a multi-unit system, use SIMPL programming.
Function name
Jog Shades Closed (All, Group 1-6)
Behavior
Specified shades will move toward the Closed position for the specified
jog time, and then stop.
LED
On while button is pressed
Applies To
Remote Button
Rocker
N/A
Behavior
Notes
Jog time defaults to 0.05 sec. Other values can be set in iLux Designer.
Shade commands with "All" parameter will only affect all the shade
groups connected to the given CLS-C6 module. They will not pass from
one CLS-C6 module to the other (either when directly connected or
when linked through Cresnet system). To accomplish this function for all
shades in a multi-unit system, use SIMPL programming.
Operations Guide - DOC. 6347B