Code 1
Code 2
63
03
The polling ID does not match.
63
04
The prompted confidential ID and mailbox ID does not match.
63
05
The relay broadcast ID does not match.
The prompted retrieval ID and mailbox retrieval ID does not
63
06
match.
63
09
There is no box number specified by F Code communications.
An SID frame was not sent during F Code remote bulletin
63
10
board registration.
An PWD frame was not sent during F Code remote confidential
63
11
retrieval.
63
12
The PIN prompted by F Code does not match.
74
XX
DCN was received.
80
01
Fallback is not possible.
A video signal or a command cannot be detected within 6
90
01
seconds after CFR sending.
A PPS that includes an invalid page count or block count was
90
02
received.
The error correction sequence was not terminated even at the
A0
03
final transmission speed for fallback.
A0
11
The receiving buffer is empty. (5-second timeout)
The receiving buffer became full during an operation other than
A0
12
receiving into memory.
A0
13
A decoding error continued to exceed 500 lines or more.
A0
14
A decoding error continued to exceed 15 seconds or longer.
A0
15
Timeout: Transmission of 1 line lasted for 13 seconds or longer.
RTC could not be detected, or the carrier off was detected for 6
A0
16
seconds.
RTC was detected but a command was not detected for 60
A0
17
seconds or longer.
A0
19
No image data to be sent.
A0
20
Color fax receiving cannot be continued (remaining ink is low).
A8
01
Receive RTN or PIN or ERR (sending side).
A9
01
Send RTN or PIN or ERR (receiving side).
AA
18
Receive buffer full during receiving into memory.
Cause
2-17
Reference
Page
Section
4.9.3 "A
communicat
ions error
occurs"
Confidential

Hide quick links: