Alarm Codes - Wine Guardian D088 Installation, Operation And Maintenance Manual

Ducted self-contained wine cellar cooling systems
Table of Contents

Advertisement

Default %RH
Default mode

Alarm Codes

High temperature
alarm
Flashing
temperature number
Low temperature
alarm
Flashing
temperature number
High humidity alarm
Flashing humidity
number
Setting 71
• Press "Settings" button to advance to
Setting 71.
No setting adjustment.
Initial relative humidity set point. Will
revert to this setting upon loss of power.
Setting 72
• Press "Settings" button to advance to
Setting 72.
• Press the "Up" or "Down" buttons to
adjust to the desired setpoint.
Initial mode set point. Will revert to this
setting upon loss of power.
1 = Auto
2 = Cool
3 = Heat
Flashing temperature number along
with (!) symbol will remain on screen
until temperature falls below the High
Temperature Alarm set point (Setting
3).
Flashing temperature number along
with (!) symbol will remain on screen
until temperature rises above the Low
Temperature Alarm set point (Setting
2).
Flashing humidity number along with (!)
symbol will remain on screen until
humidity falls below the High Humidity
Alarm setpoint (Setting 5).
44