Siemens Albatros RVS46 Series User Manual page 49

Zone controller
Table of Contents

Advertisement

request K28 ¦ Air dehumidifier K29 ¦ Diverting valve,
cooling Y21
6032
I
Relay output QX23
None ¦ Circulating pump Q4
None ¦ Circulating pump Q4
¦ Collector pump Q5
K10 ¦ 2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2
Q22 ¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump
HCP Q20 ¦ H2 pump Q18 ¦ System pump Q14 ¦
Scheduler 5 K13 ¦ DHW mixing pump Q35
iterm circ pump Q33
request K28 ¦ Air dehumidifier K29 ¦ Diverting valve,
cooling Y21
4)
6040
I
Sensor input BX21
None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW
circulation sensor B39 ¦ DHW charging sensor B36 ¦
Solar flow sensor B63 ¦ Solar return sensor B64
4)
6041
I
Sensor input BX22
None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW
circulation sensor B39 ¦ DHW charging sensor B36 ¦
Solar flow sensor B63 ¦ Solar return sensor B64
6046
I
Function input H2
Optg mode changeover HCs + DHW ¦ Optg mode
changeover HCs ¦ Optg mode changeover HC1 ¦ Optg
mode changeover HC2 ¦ Optg mode changeover HCP ¦
Error/alarm message ¦ Min flow temp setpoint ¦ Excess
heat discharge ¦ Dewpoint monitor ¦ Flow temp. setpt
increase, hygro ¦ Refrig request ¦ Heat request 10V ¦
Refrig. request 10V ¦ Pressure measurement 10V ¦ Rel.
room humidity 10V ¦ Room temperature 10V
6047
I
Contact type H2
NC ¦ NO
6048
I
Function value, contact H2
6049
I
Voltage value 1, H2
6050
I
Function value 1, H2
6051
I
Voltage value 2, H2
6052
I
Function value 2, H2
4)
6097
F
Sensor type collector
NTC 10k ¦ Platinum 1000
4)
6098
F
Readjustm collector sensor
6100
F
Readjustm outside sensor
6110
F
Time constant building
6120
F
Frost protection for the plant
Off ¦ On
6128
F
Heat request below OT
6129
F
Heat request above OT
4)
6131
F
Heat req in economy mode
Off ¦ On DHW ¦ On
6135
F
Air dehumidifier
Off ¦ On
6136
F
Air dehumidifier enable
24h/day ¦ Time progr. heating circuit ¦ Time program 5
6137
F
Air dehumidifier r.h. EIN
6138
F
Air dehumidifier r.h. SD
6200
I
Save sensors
No ¦ Yes
Siemens
Building Technologies
4)
¦
4)
¦ El imm heater DHW K6
4)
¦ H1 pump Q15 ¦ Alarm output
4)
¦ DHW
4)
¦ Heat request K27 ¦ Refrig
User Manual
QAA75.. / QAA78... / AVS37..
None
None
None
Optg mode changeover
HCs+DHW
N/O
70
8
0
0
0
-100
10
0
70
-100
NTC 10k
0
-20
0
-3.0
15
0
Off
- - -
- - - / -50
- - -
- - - / -50
Off
Off
24 h/day
55
0
5
2
No
-
130
°C
10
Volt
500
-
10
Volt
500
-
20
°C
3.0
°C
50
h
-
50
°C
50
°C
100
%
50
%
-
CE1U2353en
2014-07-30
49/138