Motor Protection - YASKAWA VS-606V7 Series Instruction Manual

Compact general-purpose inverter
Hide thumbs Also See for VS-606V7 Series:
Table of Contents

Advertisement

• Motor Protection

Motor overload detection
The VS-606V7 protects against motor overload with a built-in electronic thermal
overload relay.
• Motor rated current (electronic thermal reference current, n036)
Set to the rated current value shown on the motor nameplate.
Note:
Setting to 0.0A disables the motor overload protective function.
• Motor overload protection selection (n037, n038).
n037 Setting
0
Applied to general-purpose motor
1
Applied to inverter duty motor
2
Electronic thermal overload protection not provided
Parameters
Name
No.
Protection parameter
n038
selection
The electronic thermal overload function monitors motor temperature, based on
inverter output current and time, to protect the motor from overheating. When
electronic thermal overload relay is enabled, an "
inverter output and preventing excessive overheating in the motor. When operating
with one inverter connected to one motor, an external thermal relay is not needed.
When operating several motors with one inverter, install a thermal relay on each motor.
90
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Electronic Thermal Characteristics
Unit
Setting Range
Initial Setting
1min
1 to 60min
8min
" error occurs, shutting OFF the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents