Henny Penny Wendy's Evolution Elite EEG-251 Operator's Manual page 86

Reduced oil capacity open fryer

Advertisement

Display
"E-48"
"E-54C"
"E-60"
"E-70C"
"E-83-A"
"E-83-B"
"E-83-C"
"E-83-D"
"E-83-E"
"E-83-J"
"E-83-R"
"E-93-1"
"24 VDC
SUPPLY
TRIPPED"
72
Cause
Input system
Have PC board replaced.
error.
Temperature in-
Turn power switch to off, then back to on; have control PC
put error.
board replaced if "E-54C" persists.
AIF PC board not
Turn power switch to off, wait 15 seconds, then turn switch
communicating
back to on. If "E-60 persists, have connector between the
with PC board.
PC boards checked; replace AIF PC board or control PC
board if necessary.
Drain valve jump-
Have the jumper wire checked on the PC board at drain
er wire missing or
switch interlock position.
disconnected.
Pressure too
Check filter system in vat #1
high.
Pressure too
Check filter system in vat #2
high.
Pressure too
Check filter system in vat #3
high.
Pressure too
Check filter system in vat #4
high.
Pressure too
Check filter system in vat #5
high.
Bulk BIB fill
Check BIB fill valves
switch on when
pressure too
high.
Bulk dispose
Check Bulk Dispose quick-disconnect behind fryer.
switch on when
pressure too
high.
Autolift motor
If AutoLift feature is not operating, have each of the Auto-
malfunction or
lift motors checked.
failure.
Panel Board Correction