7 7 . . 2 2 E E r r r r o o r r C C o o d d e e s s
In the event of a control system failure, the digital display shows an error message.
The message codes are shown in the display column below. A constant tone is heard
when an error code is displayed, and to silence this tone, press any button.
Display
"E-4"
"E-5"
"E-6A"
"E-6B"
"E-10"
70
Cause
Filter pan not
Make sure filter pan return line is pushed completely into
completely
the receiver on the fryer.
engaged.
Filter pan
Clean pan and change paper or pad.
clogged.
Damaged O-ring
Replace O-ring.
on filter line re-
ceiver on fryer.
Power cord for
Plug power cord into receptacle.
vat #1 is not
plugged in.
Open circuit.
Breakers in fryer tripped; open left door and reset breaker
on fryer.
Thermal reset
Allow motor to cool, then, using a screwdriver, press hard
button on the rear
against the button until it clicks.
of the pump mo-
T T o o
p p r r e e v v e e n n t t
tor is tripped.
s s h h o o r r t t e e n n i i n n g g , , t t u u r r n n t t h h e e u u n n i i t t ' ' s s p p o o w w e e r r s s w w i i t t c c h h t t o o t t h h e e o o f f f f
p p o o s s i i t t i i o o n n b b e e f f o o r r e e r r e e s s e e t t t t i i n n g g t t h h e e f f i i l l t t e e r r p p u u m m p p m m o o t t o o r r ' ' s s
m m a a n n u u a a l l r r e e s s e e t t p p r r o o t t e e c c t t i i o o n n d d e e v v i i c c e e . .
T T a a b b l l e e 7 7 - - 2 2 E E r r r r o o r r C C o o d d e e s s
Cause
Control board
Turn switch to off position, then turn switch back to on; if
overheating.
display shows "E-4", the control board is getting too hot;
check the louvers on each side of the unit for obstruction.
Oil overheating.
Turn switch to off position, then back to on; if display
shows "E-5", the heating circuits and temperature probe
should be checked.
Temperature
Turn switch to off position, then back to on; if the display
probe open.
shows "E-6", the temperature probe should be checked.
Temperature
probe shorted.
High limit.
Let the unit cool down (15-20 minutes), push up on metal
reset button under right side of the controls; if high limit
does not reset, high limit must be replaced.
Correction
b b u u r r n n s s
c c a a u u s s e e d d
b b y y
Panel Board Correction
s s p p l l a a s s h h i i n n g g