Download Print this page

Henny Penny Wendy's Evolution Elite EEG-251 Operator's Manual page 79

Reduced oil capacity open fryer

Advertisement

Menu Step
SP-21 Auto-Lift
Press and release the right arrow until "SP-21 AUTOLIFT EN-
Enabled
ABLED?" flashes in the left display. Press the up or down arrow to
choose "YES LIFT" or "NO LIFT". If fryer is fitted with the auto-lift op-
tion, SP-21 must be set to "YES LIFT", otherwise, set SP-21 to "NO
LIFT".
SP-22 Bulk Oil
Press and release the right arrow until "SP-22 BULK OIL SUPPLY?"
Supply
flashes in the left display. Press the up or down arrow to choose "YES
SUPL" or "NO SUPL". Set to "YES" if the oil is pumped into the vat
from an outside oil reservoir. Otherwise, set SP-22 to "NO".
SP-23 Bulk Oil
Press and release the right arrow until "SP-23 BULK OIL DISPOSE?"
Disposal
flashes in the left display. Press the up or down arrow to choose "YES
DISP" or "NO DISP". Set to "YES DISP" if the oil is pumped from the
vats to an outside oil reservoir when discarding the oil. Otherwise, set
SP-23 to "NO DISP".
SP-24 Serial Num-
Press and release the right arrow until "SP-24 S/N ✓EDIT" flashes in
ber Log
the displays, along with the serial number of the unit.
NOTE: This serial number should match the serial number on the da-
ta plate, on the doors. If not, it can be recorded.
SP-25 Program
This allows the operator to change the program code (factory set at 1,
Code Change
2, 3) used to access Product Programming and Level 2 Program
Mode.
Press and release the right arrow until "SP-25 CHANGE MGR
CODE? 1=YES" flashes in the display. Press product 1 and "ENTER
NEW CODE" "P=DONE" "I=QUIT" scrolls through the display. Press
the product buttons for new code. If satisfied with the code, press the
program button and "REPEAT NEW CODE" "P=DONE" "I=QUIT"
shows in display. Enter the same code you previously entered. If sat-
isfied with code, press the program button and "CODE CHANGED*"
shows in display. If not satisfied with code, press the info button and
"*CANCEL*" shows in display, then reverts back to "SP-25"
"CHANGE MGR CODE? 1=YES". Now the above steps can be
repeated.
SP-26 Usage Code
This allows the operator to change the reset usage code (factory set
Change
at 1, 2, 3) to reset the usage amounts of each product. See
view Usage , page 52
Press and release the right arrow until "SP-26 CHANGE USAGE
CODE? 1=YES" flashes in the display. Press product 1 and "ENTER
NEW CODE" "P=DONE" "I=QUIT" scrolls through display. Press
product buttons for new code. If satisfied with code, press the pro-
gram button and "REPEAT NEW CODE" "P=DONE" "I=QUIT" shows
in the display. Enter the previously entered code. If satisfied with
code, press the program button, "*CODE CHANGED*" shows in dis-
play. If not satisfied with code, press the info button and "*CANCEL*"
shows in display the reverts back to "SP-26" "CHANGE USAGE
CODE? 1=YES". Now the above steps can be repeated.
Description
in
Chapter 4 Information Mode , page
4.5 5. Re-
49.