Reduced oil capacity open fryer

Advertisement

3 3 . . 7 7 O O I I L L G G U U A A R R D D I I A A N N ™ ™ ( ( A A u u t t o o T T o o p p - - O O f f f f ) )
During normal operation, the control automatically monitors vat oil level. If the control
senses oil level is too low, unit automatically pumps oil from BIB into vat to keep oil at
proper level.
3 3 . . 7 7 . . 1 1 M M a a n n u u a a l l T T o o p p - - O O f f f f
If oil level is a little low, oil can be added to vat at any time from BIB to raise oil level to
proper level by following steps below. This procedure is not to be used to fill an empty
vat.
Press and hold the filter button (either one for full vat) until display shows
1 1 ) )
"*FILTER MENU*" followed by "1.EXPRESS FILTER".
Press the right arrow 5 times until "6.FILL FROM BIB" shows in display.
2 2 ) )
Press "✓"; "FILL VAT" "✓=PUMP" "X=EXIT" is displayed.
3 3 ) )
Press and hold "✓"; display shows "FILLING" and oil is pumped from the BIB to
4 4 ) )
the vat.
Once vat is full, release "✓"; "FILL VAT" "✓=PUMP" "X=EXIT" displays. Press
5 5 ) )
"X" button twice for normal operation.
3 3 . . 8 8 S S e e l l e e c c t t i i n n g g A A P P r r o o d d u u c c t t W W i i t t h h A A D D i i f f f f e e r r e e n n t t S S e e t t - - P P o o i i n n t t
When selecting a product, if "XXX XXX" shows in the display, the set-point
temperature is not correct for this product. To change the set-point temperature for the
desired product:
Press product button, for ex: product 1 (FRY).
1 1 ) )
Display shows "XXX XXX".
2 2 ) )
Press and hold timer 1 or 2 for 5 seconds and then "FRY" shows in display.
3 3 ) )
Allow oil temperature to reach set-point temperature before dropping product.
4 4 ) )
3.9a Replacing the BIB
Control displays "BIB IS LOW" and an alarm sounds.
1 1 ) )
Open right door, pull BIB from unit. Pull cap from BIB top, discard empty BIB,
2 2 ) )
and replace with full one.