Menu Step
SP-8 Filter Tracking
Mode
62
set the time (0 to 60 minutes) fryer stays idle before auto-idle is en-
abled. Ex., "30" means, if product is not cooked in that vat for 30 mi-
nutes, the control automatically cools the oil down to the idle set-point
temperature. Press the right arrow and "SP-7C" "IDLE SETPT"
flashes in the left display. Press the up or down arrow, or use the
product buttons, to set idle temperature 200°F to 375°F (93°C to 191°
C).
Filter Tracking signals the operator when the oil needs filtering by
counting the number of Cook Cycles between filters.
Press and release the right arrow until "SP-8" "FILTER TRACKING
MODE" shows in the display. Use the up or down arrow to choose ei-
ther "1.MIXED" filter tracking or "2.GLOBAL".
NOTE:
GLOBAL means all the products have the same number of cook
cycles between filters
MIXED means each product may be set with different number of
cook cycles between filters. The controls add the cycle count (see
example below) and when the counts equal 1 or greater, filtering
is suggested. Ex., 1 load of fish. 2 loads of french fries, a load of
chicken equals 1. 1/2 + 1/8 + 1/8 + 1/4 = 1
Product
Fish
French Fries
Chicken
M M I I X X E E D D
If MIXED is selected, press the right arrow and SP-8A" "SUGGEST
FILTER AT..." shows in the left display, and a value between 75%
and 100 % shows on the right display. Press the up or down arrow to
change this value. The lower the value, the sooner the control recom-
mends to filter. Ex: If set to 75%, the control suggest filtering after 3/4
of the programmed cook cycles must be completed before the control
suggest filtering. Press the right arrow and "SP-8B" "LOCKOUT EN-
ABLED?" shows in the left display. Press the up or down arrow to
choose "YES or "NO". If set to "YES", when controls suggest filtering,
"FILTER LOCKOUT"/"YOU *MUST* FILTER NOW", shows in display;
more cook cycles are refused until vat is filtered. Press the right arrow
and "SP-8C" "FILTER LOCKOUT AT..." shows in left display and a
value between 100% and 250% shows on right display. Press the up
or down arrow to change this value. The lower the value, the sooner
the "lockout" occurs. Ex., If set at 100%, "lockout" occurs when the
cycle count reaches 1 or greater. Set at 200%, twice as many cycles
are counted before "lockout" occurs.
G G L L O O B B A A L L
If GLOBAL is selected, press the right arrow.
Description
No. Cook Cycles
Cycle Count
2
8
4
1/2
1/8
1/4

Advertisement