5.6 Setting the communication parameters
5.6 Setting the communication parameters
The correct values of communication parameters are vital to
ensure the correct ECR communication with its peripherals.
The communication parameters can be set for PC (931. PC),
bar-code scanner (932. Scanner), external printers (933. Print-
ers), scales (934. Scales), EFT terminal (935. EFT), and the ex-
ternal communication module (936. ECM).
1. Look up "Peripherals" in the main service mode menu or
enter code 930 and press O
900.Service mode
930.Peripherals
2. Select the peripheral using the arrow keys for which you
want to set the communication parameters or enter its
code and press O
E
K
930.Peripherals
931.PC
All menu items in the "Peripherals" menu except "Scales" con-
tains the "Default" command that sets the default values for
the selected peripheral. This command is always located as
last in the submenu.
5.6.1 Setting the communication parameters
5.6.1 Setting the communication parameters
for PC, bar-code scanner, EFT, and ECM
for PC, bar-code scanner, EFT, and ECM
The action for setting communication parameters for these
four device types is the same, except for PC that doesn't con-
tain "Active" menu item, thus PC codes are shifted by one
up. EFT contains one more menu item for setting the EFT
communication protocol (menu item 100). Press O
(N
E
) to enter that menu item and pick a protocol for
UM
NTER
EFT communication: Bull (1) or VeriFone (2). Press O
(N
E
) to confirm your selection.
UM
NTER
935.EFT
100.Protocol 1
1. Peripheral activity. Select the "Active" using the arrows or
enter code 1 and press O
rows select whether the peripheral is connected to the
ECR and press O
E
K
not connected, 1 – active/connected.
2. Communication speed in Bauds (1 Bd = 1 bit/s). Select the
932.Scanner
1.Active 1
"Baud rate" using the arrows or enter the code 2 and press
O
E
(N
E
). Set the communication speed con-
K
NTER
UM
NTER
66
E
(N
E
K
NTER
UM
NTER
>
E
(N
).
NTER
UM
NTER
|
>
E
E
(N
). Using the ar-
K
NTER
UM
NTER
(N
E
). Values: 0 – inactive/
NTER
UM
NTER
>
formant to selected peripheral own speed and press O
E
(N
NTER
3. Parity setting. Select the "Parity" using the arrows or en-
).
ter the code 3 and press O
sired parity check and press O
0 – none (no parity check), 1 – even, 2 – odd.
4. Number of stop bits. Select the "Stop bits" using the ar-
rows or enter the code 4 and press O
Set the desired number of stop bits and press O
(N
E
UM
NTER
5. Number of data transfer bits. Select the "Data bits" using
the arrows or enter the code 5 and press O
E
). Set the desired number of data bits using arrows
M
NTER
and press O
E
6. Restoring the default values. Select the "Default" using
K
NTER
the arrows or enter the code 6 and press O
E
E
). The ECR restores the default values for the se-
K
NTER
M
NTER
lected peripheral.
Note: Communication settings for the PC, scanner, and EFT
are changed only after the ECR is turned off and back on.
5.6.2 Setting the communication parameters
5.6.2 Setting the communication parameters
for external printers
for external printers
The ECR is capable of communication with seven external
printers. Individual printers are distinguished by name.
1. Select the printer you want to set the communication pa-
rameters for and press O
E
).
UM
NTER
932.Scanner
2.Baud rate 9600
E
K
NTER
E
K
932.Scanner
3.Parity 0
).
932.Scanner
4.Stop bits 1
E
(N
E
).
K
NTER
UM
NTER
932.Scanner
5.Data bits 8
932.Scanner
6.Default
E
(N
K
NTER
©
Elcom s. r. o.
K
|
(N
E
). Set the de-
UM
NTER
(N
E
). Values:
NTER
UM
NTER
|
E
(N
E
).
K
NTER
UM
NTER
E
K
NTER
|
E
(N
-
K
NTER
U
|
E
(N
-
K
NTER
U
<
E
).
UM
NTER
Euro 2500
TX
Need help?
Do you have a question about the EURO-2500 and is the answer not in the manual?
Questions and answers