Figure 4.10
Cable Connector
Assembly
Variations:
4.
.
5.
1502154 Rev D
Back Nut
Main Nut
Radiation
Sleeve
Back Nut
Apply anti-seize compound to threads and O-ring. Do not use spray lubricant.
CAUTION Do not let the center conductor contact the RF module chassis. Ensure
that the center conductor extends through the centerseizure post but extends no
more than 1/16 in (1.6 mm) beyond it so that it does not touch the RF module chassis
or housing. See Figure 4.11. Ensure that no cable scraps or foreign materials remain
within the housing.
Attach the coaxial cable to the housing:
a.
Thread the connector body into the cable entry port. Ensure that the pin extends
through the centerseizure block but does not touch anything inside the housing.
Connector Body
O-rings
Main Nut/
Connector Body
90° Elbow Connector
Not
more than
0.080 in
(2.03 mm)
diameter
External threads
located on back
nut
Housing Instructions