1 ghz amplifiers
Table of Contents

Advertisement

D
D-2
Flex Max901e 1GHz Trunk and Bridger Amplifiers
Equalizer Selection (Positive Equalization Value)
Select an equalizer from the appropriate equalizer table in Accessory Tables on page D-6 that has a
tilt as close as possible to the desired Equalization Value. If the desired equalizer value is at the
midpoint between equalizer values, select the equalizer with the lower value. When selecting an
equalizer, be sure to account for the accessory's tilt. The tilt for a particular accessory is calculated
as follows:
For example, if you calculated an Equalization Value of 2 dB, then you need an SEQ-1G-03 equalizer
because:
Cable Simulator Selection (Negative Equalization Value)
Select a cable simulator from the appropriate table in Accessory Tables on page D-6 that has a tilt as
close as possible to the desired Equalization Value. If the desired equalizer value is at the midpoint
between equalizer values, select the equalizer with the lower value. When selecting an equalizer, be
sure to account for the accessory's tilt. The tilt for a particular accessory is calculated as follows:
For example, if you calculated an Equalization Value of –2dB, then you would need an SCS-1G-03
cable simulator because:
Insertion Loss at Low Balancing Carrier
Insertion Loss at High Balancing Carrier
=
SEQ/MEQ Tilt
3.0 (Insertion Loss at 42MHz)
1.0 (Insertion Loss at 1002MHz)
=
2.0 (Tilt for SEQ-1G-03 Series Cable Equalizers)
Insertion Loss at Low Balancing Carrier
Insertion Loss at High Balancing Carrier
=
SCS Tilt
1.0 (Insertion Loss at 54MHz)
3.0 (Insertion Loss at 1002MHz)
–2.0 (Tilt for SCS-1G-03 Series Cable Simulators)
=